OPERATING HEATER

Continued

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

Pilot Burner

Ignitor Electrode

Figure 22 - Pilot

9.Slightly push in and turn control knob counterclockwise to the ON position.

10.Wait one minute and switch remote selector switch to the ON position to light burner.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

WARNING

Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with remote selector switch in the ON position.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Set remote selector switch in the OFF position to prevent draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set remote selector switch in the OFF position.

THERMOSTAT CONTROL OPERATION

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The Burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 19.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, above.

103448

Image 20
Contents VS18PR VS24PR VS30PR What to do if YOU Smell GASContents Safety InformationUnpacking Product Features Safety PilotLocal Codes OperationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceAIR for CombustionVentilation Ventilation AIRInstalling Check GAS TypeInstalling Installation and Clearances Minimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureMinimum Non Combustible Material Clearances InstallingIf Using Mantel Installing Mantel Clearances See FigureInstalling Heater Base Assembly Floor ClearancesAttaching Base to Fireplace Floor Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsTest Pressures In Excess Of 1/2 Psig Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing Logs Metal Grate BarHeater For Your Safety Read Before LightingInstalling Operating Lighting Instructions Control Knob and Ignitor Button LocationManual Lighting Procedure To Turn OFF GAS to ApplianceThermostat Control Operation Shutting Off HeaterOptional Ghrct Hand Held Remote Operation Operating HeaterFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Cleaning MaintenanceTurn off heater and let cool before cleaning ODS/PILOT and BurnersTrouble ShootingTrouble ShootingWiring Diagram Technical ServiceSpecifications Service HintsReplacement Parts Parts Under WarrantyBreakdown Illustrated PartsParts List KEY Part Numbers VS18PR VS24PR VS30PR Description QTYAccessories 103448 Warranty Information Limited Warranty VENT-FREE Propane GAS LOG Heaters

VS18PR, VS30PR, VS24PR specifications

Vanguard Heating offers a range of high-performance heating solutions, including the VS30PR, VS18PR, and VS24PR models. Each unit is engineered to deliver exceptional efficiency and reliability for both residential and commercial heating needs.

The VS30PR model is designed for medium-sized spaces, delivering up to 30,000 BTUs. Its compact design makes it an excellent choice for both homes and businesses where space is at a premium. The VS30PR is equipped with advanced modulating technology, allowing it to adjust its heating output based on the current demand, which significantly enhances energy efficiency. One of its key features is the electronic ignition system that eliminates the need for a standing pilot light, thus enhancing safety and reducing gas consumption.

On the other hand, the VS18PR model is tailored for smaller applications, providing a heating output of up to 18,000 BTUs. This model excels in energy conservation, having earned high efficiency ratings. It includes an integrated fan system that ensures uniform heat distribution throughout the space, mitigating cold spots and enhancing comfort. The VS18PR is ideal for homes with limited heating requirements or smaller commercial spaces. Its durable construction and reliable operation make it a popular choice for those seeking a dependable heating solution without unnecessary excess.

The VS24PR model offers a balanced option for larger areas with a heating capacity of up to 24,000 BTUs. It features dual fuel options, allowing users to switch between natural gas and propane, providing versatility depending on the available fuel source. The VS24PR also includes advanced control systems that allow for programmable settings, enabling users to optimize their heating schedules based on their lifestyle and preferences. An outstanding feature of this model is its compatibility with smart home systems, allowing for remote monitoring and control via smartphone applications.

Overall, Vanguard Heating’s VS30PR, VS18PR, and VS24PR models embody the brand’s commitment to quality, efficiency, and customer satisfaction. Each model incorporates innovative technologies that cater to varying heating needs, ensuring users can find an appropriate solution for their specific requirements. With robust designs and advanced features, these units not only enhance comfort but also contribute to reduced energy costs. Whether for a cozy home setting or a bustling commercial environment, Vanguard Heating’s offerings stand out for their performance and reliability.