Vanguard Heating VS30PR, VS24PR, VS18PR installation manual Attaching Base to Fireplace Floor

Page 13

INSTALLING

Continued

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant (resistant to propane (LP) gas, not provided)

electric drill with 3/16" drill bit

Note: Install optional GHRCT Receiver and Hand Held Remote Control Kit (see Accessories, page 30) before installing gas log heater. See installation instructions included with the kit.

1.Apply pipe joint sealant lightly to male threads of gas fitting. Connect approved flexible gas hose to inlet side of gas control (see Figure 10).

2.Position heater base assembly in fireplace.

3.Mark screw locations through holes in front panel of base (see Figure 11). If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks.

4.Remove heater base from fireplace.

5.Drill holes at marked locations using 3/16" masonary drill bit.

6.Attach base to fireplace floor using masonry screws (in hardware package).

7.Connect to gas supply. See Connecting To Gas Supply, page 14.

Gas Control

Flexible Gas Hose (if allowed by local codes)

Figure 10 - Attaching Flexible Gas Hose to Heater Gas Regulator

Masonry Screw

Masonry Screw

 

Figure 11 - Attaching Base to Fireplace Floor

Continued

103448

13

Image 13
Contents What to do if YOU Smell GAS VS18PR VS24PR VS30PRContents Information SafetySafety Pilot Unpacking Product FeaturesLocal Codes OperationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationCombustion AIR forVentilation Ventilation AIRCheck GAS Type InstallingMinimum Fireplace Clearance To Combustible Materials Installing Installation and ClearancesLOG Sizing Requirements Minimum Wall and Ceiling Clearances see FigureIf Using Mantel InstallingMinimum Non Combustible Material Clearances See Figure Installing Mantel ClearancesFloor Clearances Installing Heater Base AssemblyAttaching Base to Fireplace Floor Installation Items Needed Connecting to GAS SupplyGas Connection Checking GAS ConnectionsPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemTest Pressures In Excess Of 1/2 Psig Test Pressures Equal To or Less Than 1/2 PsigMetal Grate Bar Installing Installing LogsInstalling Operating For Your Safety Read Before LightingHeater Control Knob and Ignitor Button Location Lighting InstructionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterOperating Heater Optional Ghrct Hand Held Remote OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Maintenance CleaningTurn off heater and let cool before cleaning ODS/PILOT and BurnersShooting TroubleShooting TroubleTechnical Service Wiring DiagramSpecifications Service HintsParts Under Warranty Replacement PartsIllustrated Parts BreakdownKEY Part Numbers VS18PR VS24PR VS30PR Description QTY Parts ListAccessories 103448 Limited Warranty VENT-FREE Propane GAS LOG Heaters Warranty Information

VS18PR, VS30PR, VS24PR specifications

Vanguard Heating offers a range of high-performance heating solutions, including the VS30PR, VS18PR, and VS24PR models. Each unit is engineered to deliver exceptional efficiency and reliability for both residential and commercial heating needs.

The VS30PR model is designed for medium-sized spaces, delivering up to 30,000 BTUs. Its compact design makes it an excellent choice for both homes and businesses where space is at a premium. The VS30PR is equipped with advanced modulating technology, allowing it to adjust its heating output based on the current demand, which significantly enhances energy efficiency. One of its key features is the electronic ignition system that eliminates the need for a standing pilot light, thus enhancing safety and reducing gas consumption.

On the other hand, the VS18PR model is tailored for smaller applications, providing a heating output of up to 18,000 BTUs. This model excels in energy conservation, having earned high efficiency ratings. It includes an integrated fan system that ensures uniform heat distribution throughout the space, mitigating cold spots and enhancing comfort. The VS18PR is ideal for homes with limited heating requirements or smaller commercial spaces. Its durable construction and reliable operation make it a popular choice for those seeking a dependable heating solution without unnecessary excess.

The VS24PR model offers a balanced option for larger areas with a heating capacity of up to 24,000 BTUs. It features dual fuel options, allowing users to switch between natural gas and propane, providing versatility depending on the available fuel source. The VS24PR also includes advanced control systems that allow for programmable settings, enabling users to optimize their heating schedules based on their lifestyle and preferences. An outstanding feature of this model is its compatibility with smart home systems, allowing for remote monitoring and control via smartphone applications.

Overall, Vanguard Heating’s VS30PR, VS18PR, and VS24PR models embody the brand’s commitment to quality, efficiency, and customer satisfaction. Each model incorporates innovative technologies that cater to varying heating needs, ensuring users can find an appropriate solution for their specific requirements. With robust designs and advanced features, these units not only enhance comfort but also contribute to reduced energy costs. Whether for a cozy home setting or a bustling commercial environment, Vanguard Heating’s offerings stand out for their performance and reliability.