Vanguard Heating VMH26TPA installation manual Optional Mantel Installation

Page 10

® VMH26TPA

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

If your installation does not meet the above minimum clearances, you must:

raise the mantel to an acceptable height,

OR

remove the mantel.

OPTIONAL MANTEL

INSTALLATION

Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installa- tion. Refer to instructions on page 4 for firebox assembly. Blower accessory should

5.Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 12).

6.Align brass trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 12).

8.Remove brass trim kit and mantel. Be careful not to damage wall or mantel.

9.Place wood base next to wall at instal- lation location.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 13). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14).

11.Install gas line. See Connecting To Gas Supply, page 14.

12.Check for leaks. See Checking Gas Connections, page 16.

13.Place mantel around fireplace. Be care- ful not to damage wall or mantel.

14.Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 12).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the man- tel. The openings are located at top be- hind the area for the brass louvers (see Figure 13).

16.Reinstall top brass louvers.

be installed if it is being used (see Accesso- ries, page 27).

1.Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base assembly.

4.Assemble brass trim kit. See Assem- bling Brass Trim, page 11.

Mantel Shelf

Note:

10"

 

 

 

8"

 

 

 

All vertical

 

 

 

measurements

6"

 

 

 

 

 

 

are from top of

 

 

 

2 1/2"

 

 

 

fireplace

 

 

 

opening to

 

 

 

 

bottom of

 

 

 

 

mantel shelf. All

 

 

 

 

measurements

 

 

 

 

are in inches.

 

 

 

 

Side of

13"

16"

19"

21"

 

 

 

 

Firebox

 

 

 

 

 

 

 

 

Figure 11 - Minimum Mantel Clearances for Built-In Installation

Shoulder

Screws

Hole for 3" wood screw for attaching fireplace to mantel

 

Hole for 3"

 

wood screw for

 

attaching

Assembled

fireplace to

wooden base

Brass Trim

 

Figure 12 - Attaching Brass Trim to Fireplace

1 3/4" Screw

Wood

 

Base

Figure 13 - Attaching Wood Base to Floor

10

104059

Image 10
Contents VENT-FREE PROPANE/LP GAS What to do if YOU Smell GASSafety Information Compact Classic Hearth FireplaceLocal Codes Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIR Ventilation Air From Outdoors Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Assembly Installing Blower Accessory GA3400TRemoving Upper Louver Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve For Built-In Installation Extension CordSupply Connecting to GASAttaching Wood Base to Solid Floor Connecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace GAS ConnectionsChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Operating Blower To Turn OFF GAS to Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off FireplacePilot Flame Pattern Inspecting BurnerBurner Flame Pattern Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Cabinet Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Air PassagewaysIllustrated Parts Breakdown VMH26TPAParts List Description QTYService Hints SpecificationsReplacement Parts Technical ServiceAccessories Warranty Information International