OWNER’S MANUAL
INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•Phillips screwdriver
•sealant (resistant to propane/LP gas, not provided)
1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.
2.Remove screws that attach branch sup- port to fireplace (see Figure 24). Care- fully lift up branch support and remove from fireplace (see Figure 24).
3.Route flexible gas line (provided by in- staller) from manual shutoff valve into fireplace through side or rear access holes in outer casing. Route flexible gas supply line through fireplace access holes in outer casing.
Screen
BranchShipping
Support Screw
Screen
Figure 24 - Removing Branch Support From Fireplace
Shoulder Screw
Flexible
Gas
Line
NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 24). The flexible gas supply line con- nection to the manual shutoff valve should be accessible.
➞ | Gas Connector |
To Fireplace |
|
Gas |
|
Regulator |
|
Flexible Gas Line fromFlexible Gas Line from Fireplace Gas Regulator
Manual Shutoff Valve
To
External
Regulator
4. Apply pipe joint sealant lightly to male |
threads of gas connector attached to |
flexible gas line (see Figure 25). Con- |
nect flexible gas line to flexible gas line |
Provided With Fireplace
Manual Shutoff Valve Provided By Installer
➞
attached to gas regulator of fireplace |
(see Figure 25). |
5. Check all gas connections for leaks. See |
Checking Gas Connections, page 16. |
6. Replace branch support back into fire- |
place. Feed flexible gas line into fire- |
place base area while replacing branch |
support. Make sure the entire flexible |
gas line is in fireplace base area. Reat- |
tach branch support to fireplace with |
screws removed in step 2. |
Figure 25 - Attaching Flexible Gas Lines Together
Continued
104059 | 15 |