Vanguard Heating VMH26TPA AIR for Combustion and Ventilation, Providing Adequate Ventilation

Page 5

OWNER’S MANUAL

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided for adequate combustion and venti- lation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation,andnewconstructionmethodshelp reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Fire- place Location, page 6.

Confined and Unconfined Space

The National Fuel Gas Code (ANS Z223.1, 1992 Section 5.3) defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the uncon- fined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Continued

104059

5

Image 5
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GASCompact Classic Hearth Fireplace Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingInstalling Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationRemoving Upper Louver Assembly Installing Blower Accessory GA3400TInstalling Blower Assembly Assembling Brass Trim Brass trim shipped with mantelInstall the switch plate on the valve Extension Cord For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GASSupply Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace GAS ConnectionsPressure Testing Gas Supply Piping System Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat Control Operation To Turn OFF GAS to Appliance Manual Lighting ProcedureOperating Blower Shutting Off FireplaceBurner Flame Pattern Inspecting BurnerPilot Flame Pattern Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceCabinet Air PassagewaysVMH26TPA Illustrated Parts BreakdownDescription QTY Parts ListReplacement Parts SpecificationsService Hints Technical ServiceAccessories International Warranty Information

VMH26TPA specifications

The Vanguard Heating VMH26TPA is designed to provide efficient, reliable, and eco-friendly heating solutions for modern homes. This heating unit boasts a variety of advanced features and technologies that ensure optimal performance and comfort, making it a popular choice among homeowners.

One of the standout characteristics of the VMH26TPA is its high efficiency rating. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, this unit operates at a significantly lower cost compared to traditional heating systems. This means not only lower energy bills but also a reduced carbon footprint, making it a sustainable choice for environmentally-conscious consumers.

Moreover, the VMH26TPA employs innovative technologies that enhance user control and comfort. It comes equipped with a smart thermostat, allowing homeowners to adjust settings remotely using a smartphone or tablet. This feature enables precise temperature control, so users can ensure their home remains comfortable even when they are away.

The compact design of the VMH26TPA is another advantage. This unit is specially engineered to fit in smaller spaces without sacrificing performance. Its sleek and modern aesthetic also ensures that it can blend seamlessly with a variety of home decors, making it not just functional but visually appealing.

In terms of installation, the VMH26TPA features a streamlined process that is generally straightforward for professionals. This reduces the time and hassle typically associated with heating system installations. Additionally, the unit is built with durable materials that ensure longevity and reduce the likelihood of malfunction over time.

Noise levels during operation are minimal, thanks to Vanguard Heating's engineering innovations. This means homeowners can enjoy a quiet environment without interruptions from traditional heating noises.

Maintenance is made easy with the VMH26TPA, as it is designed to be user-friendly. Regular upkeep can be performed with basic tools, and Vanguard provides clear guidelines, ensuring that homeowners can keep the system in excellent working order without excessive effort or cost.

In summary, the Vanguard Heating VMH26TPA embodies efficiency, convenience, and durability. With its advanced technology, high efficiency rating, compact design, and user-friendly features, it provides an outstanding heating solution for homeowners looking to enhance their comfort while being mindful of their energy consumption. This makes it a strong contender in today's competitive heating market, appealing to a wide array of consumers.