UVS33/36
Troubleshooting
Honeywell
START
CHECK
• Gas Supply On
YES
Pilot Lights with Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main Burner
YES
NO |
| • Supply line hooked up |
|
•Shutoff valve open
•Lockout has engaged. Wait 60 seconds and try again
•For spark at electrode while
NO depressing Piezo
1/8" gap to pilot hood needed
•All wiring connections
•Replace Piezo ignitor
•For air in lines
•Thermopile needs a minimum 325mV. Adjust pilot flame height
•All wiring connections
NO |
|
|
| • Replace Thermopile |
|
|
| • Thermocouple needs a minimum | |
|
|
|
| |
|
|
|
| of 14mV. |
|
|
|
| • Defective valve. turn to pilot, |
|
|
|
| meter should read greater than |
|
|
|
| 100mV. If not, replace |
|
|
|
| • Valve is turned on |
|
|
|
| • Wall switch is not turned on. |
NO |
|
|
| Watch for grounded wires! |
|
|
| ||
|
|
|
| • Thermopile needs a minimum |
|
|
|
| 325mV. |
|
|
|
| • Plugged burner orifice |
System OK