Optional Accessories

UVS33/36 Vent-Free Heaters

Optional Accessories

Fan Kits

FK12 Fan Kit

This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK12 Fan Assembly is a fixed speed fan system and does not allow for vari- able speed control. It does not use the speed control unit or the heat sensor used in the FK24 kit.

Specifications

115 Volts / 60 Hz / .75 Amps.

Installation

The fan assembly is supplied fully wired eliminating the need for a licensed electrician to carry out the installa- tion.

1.Open the lower louvre assembly. Maneuver the fan & bracket assembly around the gas valve and lines to locate the unit against the back wall of the appli- ance, resting on the base.

2.With the protective cover removed from the self-ad- hesive 'Velcro' strips apply mild pressure to the fan & bracket unit to secure the strips to the metal panels. No further securing is required.

3.Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.

FK24 Fan Kit

This auxiliary fan system increases the efficiency of the circulation of the heating air.

The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.

Specifications

115 Volt / 60Hz / .75 Amps

Installation

The fan assembly and other components are supplied fully wired eliminating the need for a licensed electrician to carry out the installation.

If hard wiring the fan in using Method B (following) we strongly recommend the use of a licensed electrician.

1.Open the lower louvre assembly. Maneuver the fan & bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the fireplace.

2.Install the thermal sensor under the bottom of the

3.Locate the fan speed control unit. This can be fitted behind the lower louvre assembly or located remotely in a conveniently located wall mounted electrical box. Remote location of the

speed control will require suitable extension of the component wiring.

4.The power supply may be connected in two ways:

Method A

Route the 6’ lead fitted to the unit to a conveniently located wall socket.

Method B

The EB-1 receptacle box (Pt. # ZA1200) may be hard wired into the house supply. The fan lead is then plugged into the EB-1 box

Electrical Connection

The EB-1 electrical junction box is available for use with the fan kits.

Remote Controls

Optional remote control units are available to control different functions of the appliance.

Model

Function(s) Controlled

RC1

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

Outside Air Termination

The AK-1 completes the connection from outside air kit to out-of-doors. (Does not include 4" flex duct.)

Ceramic Brick Liner

Ceramic panels are available to line the firebox area.

Model 33BDVCR

Decorative Bay Screen Kit

The 33BSTK Bay Window Screen Kit is available to

place on the front of the unit.

firebox, locating it over the two 10 mm studs and secure it with nuts.

20002211

19

Image 19
Contents Vent-FreeGas Room Heaters BEFORE INSTALLING AND USING HEATERSPLEASE READ THIS MANUAL Homeowners Installation andUVS33/36 Vent-FreeHeaters Table of Contents20002211 20002211 Installation & Operating InstructionsCalifornia Health & Safety Code Sec UVS33/36 Vent-FreeHeaters20002211 Fireplace DimensionsFireplace Dimensions UVS33/36 Vent-FreeHeatersClearance to Combustibles Safety DevicesDescription Orifice Conversion InstructionsMounting the Heater MantelsHearth Extension PlanningUVS33/36 Vent-FreeHeaters FramingInsulating for Cold Climates Gas SpecificationsGas Inlet and Manifold Pressures Electrical ConnectionUVS33 / UVS36 Certified To ANSI Z 21.11.2a-2003 Unvented Room HeatersUVS33/36 Vent-FreeHeaters Hard Direct Wire Hook-UpRemote Wall Switch EB1 Receptacle Hook-Up20002211 Alternate Switch LocationFinishing UVS33/36 Vent-FreeHeatersWindow Frame Removal Log Installation UVS33Operating Instructions Top Louvre Grille RemovalLava Rock Log Installation UVS36Ember Material Placement Flame AdjustmentTurn clockwise Flame CharacteristicsUVS33/36 Vent-FreeHeaters counterclockwiseLighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTINGTo Turn Off Gas to Heater Lighting and Operating InstructionsSTART TroubleshootingHoneywell UVS33/36 Vent-FreeHeaters20002211 MaintenanceCleaning the Standing Pilot Control System UVS33/36 Vent-FreeHeatersUVS33 UVS33/36 Vent Free Gas Room HeaterUVS33/36 Vent-FreeHeaters DescriptionUVS33/36 Vent-FreeHeaters UVS33/36 Vent Free Gas Room Heater continued20002211 Outside Air Termination Optional AccessoriesRemote Controls Fan Kits20002211 Decorative Frame TrimsGlass/Catalyst Kit UVS33/36 Vent-FreeHeaters20002211 Decorative Bay WindowInstallation UVS33/36 Vent-FreeHeaters20002211 UVS33/36 Vent-FreeHeaters2DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF LIMITED LIFETIME WARRANTYPRODUCT COVERED BY THIS WARRANTY IF WARRANTY SERVICE IS NEEDED…CFM Corporation CFM Corporation