Planning Information

Majestic Fireplaces® BR/BC Series

Planning Information

Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run.

Mounting the Fireplace

A fireplace may only be mounted on the following sur- faces:

1.A flat combustible surface.

2.A raised wooden platform.

3.A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.

The fireplace must be spaced 1/2" (13mm) from a com- bustible back wall and 1/2" (13mm) from a combustible side wall or support. (Page 14, Fig. 20)

Planning the Chimney Run

L

 

T

 

TOTAL

INSTALLED

 

 

 

MODEL SK

LENGTH

LENGTH

 

 

 

2 WALL CHIMNEY

(LT)

(L1)

 

 

 

 

 

 

L

 

1

SK81

�����"

�����"

 

 

 

 

SK818

�����"

�����"

 

 

 

L

 

1

SK83

�����"

�����"

 

 

 

SK84

�����"

�����"

 

 

 

 

 

 

 

FP288

Fig. 7 Installed lengths of chimney sections.

Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 6) Never install a chimney below minimum heights.

In planning a chimney system, it is important to know:

1.The height of a chimney is measured from the hearth to the exit point on the termination.

2.A chimney cannot be offset more than 30° from a vertical plane.

3.A chimney may run straight up or it may be neces- sary to offset it to avoid obstructions.

4.The maximum length of an angled run (total chimney system) is 20' (6 m).

5.No more than 2 offsets (4 total 30° elbows in U.S./or 2 total 45° elbows in Canada) per fireplace may be used.

6.A guy wire stabilizer is required for chimneys extend- ing more than 6' (1.8 m) above a roof line.

The Ten Foot Rule

Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 8)

The key points of the "Ten Foot Rule" are:

1.If the horizontal distance from the chimney to the peak of the roof is 10' (3m) or less, the top of the chimney must be at least 2' (610mm) above the peak of the roof, but never less than 3' (914mm) in height above the highest point where it passes through the roof.

2.If a horizontal distance from the chimney to the peak of the roof is more than 10' (3m), a chimney height reference point is established on the surface of the roof a distance of 10' (3m) from the chimney in a horizontal plane. The top of the chimney must be at least 2' (610mm) above the reference point, but never less than 3' (914mm) in height above the high- est point where it passes through the roof.

 

0 To 10'

 

 

2' Min. 3'

0 To 10'

 

Min.

 

 

 

2' Min. 3'

 

 

Min.

 

Reference

 

 

Point

 

 

 

AC246

Fig. 8

Ten Foot Rule illustration.

 

7412944

7

Image 7
Contents Homeowners Installation and Operating Manual Woodburning FireplaceBR36 BR42 BC36 BC42 DO NOT DISCARD THIS MANUAL Retain for future useMajestic Fireplaces BR/BC Series Safety InformationTable of Contents PrecautionsFig. 1 BR36 Series specifications and framing BR36 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series 7412944Fig. 3 BR42 Series specifications and framing BR42 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series 7412944Back Width Chase InstallationMajestic Fireplaces BR/BC Series Front WidthMajestic Fireplaces BR/BC Series Chimney Requirements - Offset Installations30˚ Elbow Offsets Illustration KeyThe Ten Foot Rule Planning InformationMounting the Fireplace Planning the Chimney RunInsulating Fireplace Enclosure for Cold Climates InstallationChase Installation Chimney SupportsOption For Circulating Models Only Installing Electrical Wire for Circulator ModelsInstall Fan Kit Assembly FramingCutting the Hole Straight-UpChimney InstallationOffset Installation Ceiling Chimney Hole Possible Obstructions7412944 Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit Majestic Fireplaces BR/BC Seriesin the Ceiling Hole Installing the Chimney SystemInstalling the Firestop Spacer Proper Firestop Spacer InstallationPenetrating the Roof Continue Installing Pipe to Complete RunCanadian Requirements for Insulation Shield Additional CeilingsFinishing Install Remainder of Chimney SectionsInstalling Top Housing or Termination Installing Chimney In a ChaseMantel Clearance - Radiant Majestic Fireplaces BR/BC Series7412944 Mantel Clearance - Radiant Model - NoMinimum Wall Clearances Hearth InstallationMinimum Hearth Extension Dimensions Side Wall ProtectionExample for Common Brick COMMON MATERIALS AND FACTORSRecessed Installation - BR/BC36 Only Majestic Fireplaces BR/BC SeriesMajestic Fireplaces BR/BC Series Installing Line For Gas Log7412944 BR/BC36 BR/BC SERIESMajestic Fireplaces BR/BC Series Item/Model NumberMajestic Fireplaces BR/BC Series Accessories7412944 Majestic Fireplaces BR/BC Series Chimney Components7412944 Majestic Fireplaces BR/BC Series Chimney Components cont. Canada7412944 C. Fan Motor LIMITED WARRANTY & 30 YEAR PROTECTION PLAN7412944 B. Firegrate, Glass Doors, Outside Air SystemCFM Corporation