Majestic Appliances BC42, BR42 Canadian Requirements for Insulation Shield, Additional Ceilings

Page 13
Canadian Requirements for

Firestop spacers are not available for nor are they re- quired on vertical walls.

DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard.

Canadian Requirements for

Insulation Shield

In Canada, an attic insulation shield is required to prevent attic insulation from contacting the chimney section. NOTE: If the attic insulation shield is used, the firestop is not required in the attic installation. Fram- ing dimensions for the chimney hole should measure 14¹⁄" x 14¹⁄" (368 x 368mm). An attic shield MUST be installed on top of attic joists (above the floor level). (Fig. 19)

NOTE: In the U.S., it is a good idea, although not al- ways required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic.

Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof.

Attic Insulation Shield Continue Installing Pipe to Complete Run

Nails

(4 required)

Additional CeilingsPenetrating the RoofLocate Chimney Centerpoint On Roof Attic Joist

Base

Ceiling Flanges

FP263

Fig. 19 Attic shield installlation (Canadian requirement).

Continue Installing Pipe to Complete Run

Continue attaching pipe sections to complete system to next level always being careful that the pipe is firmly snapped locked in place before proceeding to next pipe section.

Chimney Supports

If chimney supports are required, they are installed the same as elbows. Nail chimney support straps to ad- jacent structural framing, as shown on Figure 9, Page

8.Bend straps as necessary and make sure they are secure so they will support the weight of the chimney.

Majestic Fireplaces® BR/BC Series

A chimney support is 2¹⁄" (64mm) long when installed. Consider this dimension when determining how many straight chimney sections are needed.

NOTE: Chimney supports are generally used in long runs in a chase installation.

Additional Ceilings

If you encounter additional ceilings, repeat same steps required for first ceiling installation. See firestop illus- tration on Page 12, Figure 18.

Penetrating the Roof

Run pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved termination.

If a chase is used, refer to the installation manual pro- vided with the termination cap.

Locate Chimney Centerpoint On Roof

Use same procedure detailed in locating center point of the flue system.

Drive a nail up through roof at the center point. This will determine center point on outside of the roof.

Cut and Frame Roof Hole

Size of roof hole varies with the type of chimney termination installed. Refer to installation instructions provided with the chimney termination to find correct size of roof hole.

There must be a 1¹⁄" (38mm) air space between out- ermost portion of chimney sections and any adjacent combustible surfaces. (Combustible surfaces include burnable materials such as: ceiling members, joists, flooring, combustible insulation and roof structures.)

WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.

Mark an outline of the roof hole around the center of the point nail. NOTE: Hole dimensions given in the chimney top installation instructions are horizontal dimensions; therefore, the hole size must be marked on the roof ac- cordingly.

Cover the opening of the installed chimney so debris cannot get into the system.

Cut and frame the hole. It is good practice to use fram- ing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flash- ing anchored to the frame must be able to withstand heavy winds.

7412944

13

Image 13
Contents BR36 BR42 BC36 BC42 Woodburning FireplaceDO NOT DISCARD THIS MANUAL Retain for future use Homeowners Installation and Operating ManualTable of Contents Safety InformationPrecautions Majestic Fireplaces BR/BC SeriesMajestic Fireplaces BR/BC Series BR36 Series Woodburning Fireplace7412944 Fig. 1 BR36 Series specifications and framingMajestic Fireplaces BR/BC Series BR42 Series Woodburning Fireplace7412944 Fig. 3 BR42 Series specifications and framingMajestic Fireplaces BR/BC Series Chase InstallationFront Width Back Width30˚ Elbow Offsets Chimney Requirements - Offset InstallationsIllustration Key Majestic Fireplaces BR/BC SeriesMounting the Fireplace Planning InformationPlanning the Chimney Run The Ten Foot RuleChase Installation InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesInstall Fan Kit Assembly Installing Electrical Wire for Circulator ModelsFraming Option For Circulating Models OnlyOffset Installation Straight-UpChimney InstallationCeiling Chimney Hole Possible Obstructions Cutting the HoleInstalling Outside Air Kit Positioning, Safety Strips Securing the FireplaceMajestic Fireplaces BR/BC Series 7412944Installing the Firestop Spacer Installing the Chimney SystemProper Firestop Spacer Installation in the Ceiling HoleCanadian Requirements for Insulation Shield Continue Installing Pipe to Complete RunAdditional Ceilings Penetrating the RoofInstalling Top Housing or Termination Install Remainder of Chimney SectionsInstalling Chimney In a Chase Finishing7412944 Majestic Fireplaces BR/BC SeriesMantel Clearance - Radiant Model - No Mantel Clearance - RadiantMinimum Hearth Extension Dimensions Hearth InstallationSide Wall Protection Minimum Wall ClearancesRecessed Installation - BR/BC36 Only COMMON MATERIALS AND FACTORSMajestic Fireplaces BR/BC Series Example for Common BrickMajestic Fireplaces BR/BC Series Installing Line For Gas Log7412944 Majestic Fireplaces BR/BC Series BR/BC SERIESItem/Model Number BR/BC36Majestic Fireplaces BR/BC Series Accessories7412944 Majestic Fireplaces BR/BC Series Chimney Components7412944 Majestic Fireplaces BR/BC Series Chimney Components cont. Canada7412944 7412944 LIMITED WARRANTY & 30 YEAR PROTECTION PLANB. Firegrate, Glass Doors, Outside Air System C. Fan MotorCFM Corporation