Majestic Appliances BC36 Install Remainder of Chimney Sections, Installing Chimney In a Chase

Page 14
Install Remainder of Chimney Sections

Majestic Fireplaces® BR/BC Series

Install Remainder of Chimney Sections

Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height.

Check the chimney top installation instructions for details on how high above the roof top the chimney sec- tions (all pipes) should extend.

Installing Top Housing

or Termination

Follow the installation instructions provided with the chimney termination you have selected.

Installing Chimney In a Chase

Refer to Page 5, Figure 5 for an illustration of a typical chase installation.

CAUTION: Treatment of firestop spacers and construc- tion of chase may vary with type of building. These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTE: Other building materials may be required in addition to Firestop Spacers.

Finishing

CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with noncombustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20)

Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305mm) from the top of the fireplace opening for radiant models and 12" (305mm) from top of grille opening for circulating models. Do not install a mantel face plate less than 6" (159mm) from top of fireplace opening for radiant models and 6" (159mm) from top of grille opening for circulating models. (Fig. 22) If a combustible material is used be- low a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.

All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figures 21 and 22)

NOTE: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation).

Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).

1���" (SK8)

2" (3-WALL)

Standoff

���" air space

 

to sides

 

Front View

Side View

 

Firestop

Wall

1/2" (13 mm

Shield

Air Space

 

to Back

 

1/2" (13 mm

 

Air Space

 

to Sides

Only noncombustible

0" Clearance

 

to Floor

 

material may be applied

Hearth

 

as facing to the black

 

fireplace surround.

Extension

FP559

 

 

Fig. 20 Minimum clearances to combustibles.

 

Often a decorative surround or vertical portion of the mantel is desired. If this is constructed of any combus- tible material it must be within the safe zone indicated in Figure 23.

14

7412944

Image 14
Contents DO NOT DISCARD THIS MANUAL Retain for future use Woodburning FireplaceBR36 BR42 BC36 BC42 Homeowners Installation and Operating ManualPrecautions Safety InformationTable of Contents Majestic Fireplaces BR/BC Series7412944 BR36 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series Fig. 1 BR36 Series specifications and framing7412944 BR42 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series Fig. 3 BR42 Series specifications and framingFront Width Chase InstallationMajestic Fireplaces BR/BC Series Back WidthIllustration Key Chimney Requirements - Offset Installations30˚ Elbow Offsets Majestic Fireplaces BR/BC SeriesPlanning the Chimney Run Planning InformationMounting the Fireplace The Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Installing Electrical Wire for Circulator ModelsInstall Fan Kit Assembly Option For Circulating Models OnlyCeiling Chimney Hole Possible Obstructions Straight-UpChimney InstallationOffset Installation Cutting the HoleMajestic Fireplaces BR/BC Series Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit 7412944Proper Firestop Spacer Installation Installing the Chimney SystemInstalling the Firestop Spacer in the Ceiling HoleAdditional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements for Insulation Shield Penetrating the RoofInstalling Chimney In a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination FinishingMantel Clearance - Radiant Model - No Majestic Fireplaces BR/BC Series7412944 Mantel Clearance - RadiantSide Wall Protection Hearth InstallationMinimum Hearth Extension Dimensions Minimum Wall ClearancesMajestic Fireplaces BR/BC Series COMMON MATERIALS AND FACTORSRecessed Installation - BR/BC36 Only Example for Common Brick7412944 Installing Line For Gas LogMajestic Fireplaces BR/BC Series Item/Model Number BR/BC SERIESMajestic Fireplaces BR/BC Series BR/BC367412944 AccessoriesMajestic Fireplaces BR/BC Series 7412944 Chimney ComponentsMajestic Fireplaces BR/BC Series 7412944 Chimney Components cont. CanadaMajestic Fireplaces BR/BC Series B. Firegrate, Glass Doors, Outside Air System LIMITED WARRANTY & 30 YEAR PROTECTION PLAN7412944 C. Fan MotorCFM Corporation