To verify if the fan tray upgrade is installed on a Netra CT 900 server, log into the Shelf Manager and issue the following command for fan trays 1,2, and 3:

#clia fruinfo fan_tray 1 grep "Product Part"

If the “Product Part/Model Number” is 370-7764-xx, the fan trays must be replaced with high-speed fan trays. Refer to the Netra CT 900 Server Upgrade Guide (820-3255) for more information.

If the “Product Part/Model Number” is 371-3033-xx or newer, an upgraded fan tray is already installed.

2.2.2.2Installing Optional Components

Use the following table to locate your options and installation instructions.

DIMMs

“DIMM Requirements” on page 2-19

 

“Installing a DDR2 DIMM” on page 2-21

Compact Flash card

“Installing the Optional Compact Flash Card” on page 2-24

AMC

“Compact Flash Location” on page 2-26

 

 

2.2.2.3Configuring the Advanced Rear Transition Module (ARTM)

If you are using one of the Netra advanced rear transition modules (ARTMs), refer to the documentation: Netra CP32x0 SAS Storage Advanced Rear Transition Module, Dual HD User’s Guide (820-3147) (ARTM-HD)

See Section B.3, “Connectors and Pinouts” on page B-2 for detailed connector pin assignments for the Sun Netra CP3250 blade server.