2-24 Sun Netra CP3250 Blade Server User’s Guide • April 2009
FIGURE2-7 Removing a DIMM
5. If you are replacing the DIMM you removed with a new DIMM, install it as
described in Section 2.3.6.2, “Installing a DDR2 DIMM” onpage 2-21.
2.3.7 Installing the Optional Compact Flash Card
An IDE Compact Flash card can be installed on the Sun Netra CP3250 blade server.
The Compact Flash cardis not hot-swappable,and there is no access to the Compact
Flash card once the Sun Netra CP3250 blade server is installed in an ATCAshelf.
1. Access the blade server by performing one of the following procedures:
If the Sun Netra CP3250 blade server is installed in an ATCAshelf, remove the
blade server from the shelf as explained in Section2.3.3, “Removing the Netra
CP3250 Blade Server” on page 2-18.
Remove the Sun Netra CP3250 blade server from its antistatic envelope and place
it on an ESD mat near the ATCAshelf.
If an ESD mat is not available, you can place the blade server on the antistatic
envelope in which it was packaged.
Caution – Do not place blade servers on top of an antistatic bag unless the outside
of the bag also has antistatic protective properties.