FIGURE 2-7Removing a DIMM

5.If you are replacing the DIMM you removed with a new DIMM, install it as described in Section 2.3.6.2, “Installing a DDR2 DIMM” on page 2-21.

2.3.7Installing the Optional Compact Flash Card

An IDE Compact Flash card can be installed on the Sun Netra CP3250 blade server. The Compact Flash card is not hot-swappable,and there is no access to the Compact Flash card once the Sun Netra CP3250 blade server is installed in an ATCA shelf.

1. Access the blade server by performing one of the following procedures:

If the Sun Netra CP3250 blade server is installed in an ATCA shelf, remove the blade server from the shelf as explained in Section 2.3.3, “Removing the Netra CP3250 Blade Server” on page 2-18.

Remove the Sun Netra CP3250 blade server from its antistatic envelope and place it on an ESD mat near the ATCA shelf.

If an ESD mat is not available, you can place the blade server on the antistatic envelope in which it was packaged.

Caution – Do not place blade servers on top of an antistatic bag unless the outside of the bag also has antistatic protective properties.

2-24Sun Netra CP3250 Blade Server User’s Guide • April 2009

Page 58
Image 58
Sun Microsystems CP3250 manual Installing the Optional Compact Flash Card, 7Removing a Dimm