To reset the jumper and return the CMOS settings to the default settings, perform the following steps:

1.Remove the jumper housing from the run position (P2/32) and move it to the reset position (P1/P2).

2.Wait at least one second for the CMOS settings to reset and then move the jumper housing back to the run position (FIGURE 2-12).

3.Reinstall the blade server.

Use the procedure in Section 2.2.3.2, “Installing the Blade Server Into the Shelf” on page 2-11.

Note – The blade server will operate normally only when the jumper housing is in the run position.

2.3.10.2Changing the OOS LED Color Using Jumper 13

The color of the Out-of-service (OOS) LED can be set to red or amber by moving jumper 13 to the appropriate position. Amber is the default color for the OOS LED.

To change the Jumper 13 position to display a red OOS LED:

1.Remove the jumper housing from the default (amber) position (P2/P3) and move it to the red position (P1/P2).

2.Reinstall the blade server.

Use the procedure in Section 2.2.3.2, “Installing the Blade Server Into the Shelf” on page 2-11.