2.3.10Changing Jumper Settings

Jumpers and their switches are located near the heatsink on the blade server.

2.3.10.1Clearing the CMOS Setting Using Jumper 2

Reset jumper 2 to clear the CMOS settings, which restores the default BIOS settings.

Jumper 2 is shown in FIGURE 2-12. The jumper housing should be stored in the P2/P3 position, which is the run position.

FIGURE 2-12Jumper 2 in the Default Run Position

TABLE 2-4provides information on the pin functions on jumper 2.

TABLE 2-4Pin Functions on Jumper 2

Pin Number

Purpose

 

 

Pin 1

Battery Feed

Pin 2

VCC_RTC (destination for battery

 

power)

Pin 3

BATT_CLR (resistor to GND, used to

 

drain capacitive charge and clear the

 

CMOS memory)

 

 

Chapter 2 Hardware Installation and Service 2-31

Page 65
Image 65
Sun Microsystems CP3250 manual Changing Jumper Settings, Clearing the Cmos Setting Using Jumper, 4Pin Functions on Jumper