FIGURE B-6.

B.3.4 Data Transport Connector (Zone 2)

The data transport connector consists of two 120-pin HM-Zd connectors, labeled P20 and P23, with 40 differential pairs each. These are called the Zone 2 connectors.

The Zone 2 connectors provides the following signals:

Two 10/100/1000BASE-T/TX Ethernet base fabric channels (four differential signal pairs each; 16 signals total)

Two 10-Gbit SERDES ports on the extended fabric (eight differential signal pairs each; 32 signals total)

The connector vendor part number is Tyco: 1469001-1.

FIGURE B-5Zone 2 Connector

B.3.5 Advanced Rear Transition Module (ARTM) Connector (Zone 3)

The Sun Netra CP3250 blade server provides all the I/O connections for rear access through the Zone 3 advanced rear transition module (ARTM) connector. The connector view and the pinout for the Zone 3 connector are shown in

B-8Sun Netra CP3250 Blade Server User’s Guide • April 2009