TABLE B-9Zone 3 Signal Descriptions (Continued)

Signal Name

Description

 

 

ACT_LED#

LAN 0 (Management) activity indicator signal for LED (active low).

LINK_LED#

LAN 0 (Management) LINK indicator signal for LED (active low).

PCI_CFG

PCI Express bus configuration signal. It shall be grounded on RTMs that use a single x8

 

PCI Express bus and pulled up on the ATCA with 10Kohm resistor to management

 

power. On RTMs that expect two x4 PCI-Express busses this pin will float (not be

 

connected). Two x4 PCI-Express busses are intended for RTM implementations that

 

desire to avoid PCI-Express switch in order to reduce latency.

ARTM#

ARTM# signal shall be grounded on ARTMs that implement MMC controller as defined

 

by AMC.0 specification. This signal shall be pulled up with 10Kohm resistor to

 

management power on the ATCA node blade server.

SLAN_TX

GBEthernet SerDes transmit differential pair signals.

SLAN_RX

GBEthernet SerDes receive differential pair signals.

PETx

PCI-Express transmit differential pair signals.

PERx

PCI-Express receive differential pair signals.

PCI_RST#

PCI-Express reset signal. Logic low shall reset downstream PCI-Express devices on

 

ARTM.

TCLKA

PCI-Telecom clock A 19.44MHz, differential pair into RTM (ATCA CLK2) as defined in

 

AMC.0 specification.

TCLKB

PCI-Telecom clock B 19.44MHz, differential pair out from RTM (ATCA CLK3) as defined

 

in AMC.0 specification.

TCLKC

PCI-Telecom clock C 8kHz, differential pair into RTM (ATCA CLK1) as defined in AMC.0

 

specification.

TCLKD

PCI-Telecom clock D 8kHz, differential pair out from RTM as defined in AMC.0

 

specification.

FCLKA

Fabric clock, as defined in AMC.0 specification. Intended to be used for PCI-Express 100

 

MHz spread spectrum clock.

TCK, TMS, TRST#,

JTAG signals. Signal direction shall follow AMC.0 specification.

TDO, TDI

 

 

 

B-14Sun Netra CP3250 Blade Server User’s Guide • April 2009