TABLE C-1Shelf Manager CLI Command Summary (Continued)

Command

Parameters

Description

 

 

 

setfanlevel

IPMB address

 

FRU device ID

 

level

setfanpolicy

IPMB address

 

FRU device ID

 

action to be taken: ENABLE or DISABLE

 

timeout (optional)

 

site type (optional)

 

site number (optional)

Sets a new level for the fan controlled by the specified FRU.

Use clia setfanlevel 20 3 5 to get the fans to slow down.

Enables or disables fan trays for cooling management in addition to the Fan Geography record if this one is presented in the Shelf FRU.

setthreshold

IPMB address

 

sensor name

 

sensor number

 

threshold type

 

threshold value

setuserlabel

shelf name

 

slot number name

shelf

subcommand, with its parameters

Changes a specific threshold value (upper/lower, critical/non-critical/non-recoverable) for a specific sensor.

Configures user assigned names for the shelf and the blade servers. Blade server names are assigned to slot numbers.

Shows general information about the shelf; several subcommands allow setting shelf attributes and getting additional information about specific areas.

shelfaddress

Shelf Address string (optional)

Gets or sets the Shelf Address field of the

 

 

Address Table within Shelf FRU

 

 

Information.

shelf address_table

 

Shows the address table record in the

 

 

shelf FRU info with shelf address and list

 

 

of address table entries. For each entry,

 

 

shows hardware address, site type, and

 

 

site number.

shelf cooling_state

 

Shows the current cooling state of the

 

 

shelf with normal, minor, major, and

 

 

critical alert information.

shelf fans_state

 

Shows the current state of the fan

 

 

techometers in the shelf with normal,

 

 

minor, major and critical alert

 

 

information.

shmstatus

 

Shows the Shelf Manager Active/Backup

 

 

status.

 

 

 

Appendix C ShMM CLI and Commands

C-5

Page 131
Image 131
Sun Microsystems CP3250 manual Level