Appendix C ShMM CLI and Commands C-5
setfanlevel IPMB address
FRU device ID
level
Setsa new level for the fan controlled by
the specifiedFRU.
Useclia setfanlevel 20 3 5to get
the fans to slow down.
setfanpolicy IPMB address
FRU device ID
actionto be taken: ENABLE or DISABLE
timeout (optional)
site type (optional)
site number (optional)
Enables or disables fan trays for cooling
management in addition to the Fan
Geographyrecord if this one is presented
in the Shelf FRU.
setthreshold IPMB address
sensor name
sensor number
thresholdtype
thresholdvalue
Changes a specificthreshold value
(upper/lower,
critical/non-critical/non-recoverable)for
a specificsensor.
setuserlabel shelf name
slot number name
Configuresuser assigned names for the
shelf and the blade servers. Blade server
names are assigned to slot numbers.
shelf subcommand, with its parameters Shows general information about the
shelf; several subcommands allow
setting shelf attributes and getting
additional information about specific
areas.
shelfaddress Shelf Address string (optional) Getsor sets the Shelf Address field of the
AddressTable within Shelf FRU
Information.
shelf address_table Shows the addresstable record in the
shelfFRU info with shelf address and list
of addresstable entries. For eachentry,
shows hardwareaddress, site type, and
site number.
shelf cooling_state Shows the current cooling state of the
shelf with normal, minor,major, and
critical alert information.
shelf fans_state Shows the currentstate of the fan
techometers in the shelf with normal,
minor,major and critical alert
information.
shmstatus Showsthe Shelf Manager Active/Backup
status.
TABLEC-1 Shelf Manager CLI Command Summary (Continued)
Command Parameters Description