TABLE C-1 Shelf Manager CLI Command Summary (Continued)
Command | Parameters | Description |
|
|
|
setfanlevel | IPMB address |
| FRU device ID |
| level |
setfanpolicy | IPMB address |
| FRU device ID |
| action to be taken: ENABLE or DISABLE |
| timeout (optional) |
| site type (optional) |
| site number (optional) |
Sets a new level for the fan controlled by the specified FRU.
Use clia setfanlevel 20 3 5 to get the fans to slow down.
Enables or disables fan trays for cooling management in addition to the Fan Geography record if this one is presented in the Shelf FRU.
setthreshold | IPMB address |
| sensor name |
| sensor number |
| threshold type |
| threshold value |
setuserlabel | shelf name |
| slot number name |
shelf | subcommand, with its parameters |
Changes a specific threshold value (upper/lower,
Configures user assigned names for the shelf and the blade servers. Blade server names are assigned to slot numbers.
Shows general information about the shelf; several subcommands allow setting shelf attributes and getting additional information about specific areas.
shelfaddress | Shelf Address string (optional) | Gets or sets the Shelf Address field of the |
|
| Address Table within Shelf FRU |
|
| Information. |
shelf address_table |
| Shows the address table record in the |
|
| shelf FRU info with shelf address and list |
|
| of address table entries. For each entry, |
|
| shows hardware address, site type, and |
|
| site number. |
shelf cooling_state |
| Shows the current cooling state of the |
|
| shelf with normal, minor, major, and |
|
| critical alert information. |
shelf fans_state |
| Shows the current state of the fan |
|
| techometers in the shelf with normal, |
|
| minor, major and critical alert |
|
| information. |
shmstatus |
| Shows the Shelf Manager Active/Backup |
|
| status. |
|
|
|
Appendix C ShMM CLI and Commands |