C-6 Sun Netra CP3250 Blade Server User’s Guide • April 2009
Most informational commands support brief and verbose modes of execution,
differing in the amount of information provided. Brief mode is the default
(standard); verbose mode is selected by using the option -v in the command line,
directlyafter the command and before the positional arguments. Commands that are
executed on the backup Shelf Manager can only access objects (such as sensors,
FRUs, IPM controllers) that are local to the backup Shelf Manager.
Tohelp the user to determine whether a specific command is being executed on the
active or on the backup Shelf Manager,the following message is issued when a CLI
command is executed on the backup Shelf Manager: Running on the Backup
Shelf Manager, with limited functionality.
showhost slot-number Displays version information about the
firmwareon certain Netra CP3x60 node
blade servers.
showunhealthy Shows the unhealthy components of the
shelf.
switchover Initiatesa switchover to the backup Shelf
Manager.
terminate Terminatesthe Shelf Manager without
rebootingthe shelf managementcard.
version Shows the Shelf Manager version
information.
TABLEC-1 Shelf Manager CLI Command Summary (Continued)
Command Parameters Description