Majestic Appliances BC36, BR42 Chimney Components cont. Canada, Majestic Fireplaces BR/BC Series

Page 22
(Chimney Components con't.) Canada

Majestic Fireplaces® BR/BC Series

(Chimney Components con't.) Canada

Component

Description

Model Number

 

 

 

Chimney Collar Enclosure

Installs on the "over the chimney collar" of the

CCE-SK

 

fireplace; provides outside air to assist in cooling

 

 

the chimney system.

 

Attic Insulation Shield

Used to prevent insulation from coming in

AIS-SK

 

contact with the chimney system.

 

SK8 Chimney Sections

Used to build chimney systems exposed above

SK818CAN (1¹⁄₂' Long)

 

roof.

SK84CAN (4' Long)

45˚ Chimney Elbows

Provides 45˚ offset and return. For Canadian

SK845/2

 

installations only. For use with SK8 chimney only.

 

 

(Maximum use of 2, or 1 pair.)

 

 

 

 

22

7412944

Image 22
Contents DO NOT DISCARD THIS MANUAL Retain for future use Woodburning FireplaceBR36 BR42 BC36 BC42 Homeowners Installation and Operating ManualPrecautions Safety InformationTable of Contents Majestic Fireplaces BR/BC Series7412944 BR36 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series Fig. 1 BR36 Series specifications and framing7412944 BR42 Series Woodburning FireplaceMajestic Fireplaces BR/BC Series Fig. 3 BR42 Series specifications and framingFront Width Chase InstallationMajestic Fireplaces BR/BC Series Back WidthIllustration Key Chimney Requirements - Offset Installations30˚ Elbow Offsets Majestic Fireplaces BR/BC SeriesPlanning the Chimney Run Planning InformationMounting the Fireplace The Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Installing Electrical Wire for Circulator ModelsInstall Fan Kit Assembly Option For Circulating Models OnlyCeiling Chimney Hole Possible Obstructions Straight-UpChimney InstallationOffset Installation Cutting the HoleMajestic Fireplaces BR/BC Series Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit 7412944Proper Firestop Spacer Installation Installing the Chimney SystemInstalling the Firestop Spacer in the Ceiling HoleAdditional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements for Insulation Shield Penetrating the RoofInstalling Chimney In a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination FinishingMantel Clearance - Radiant Model - No Majestic Fireplaces BR/BC Series7412944 Mantel Clearance - RadiantSide Wall Protection Hearth InstallationMinimum Hearth Extension Dimensions Minimum Wall ClearancesMajestic Fireplaces BR/BC Series COMMON MATERIALS AND FACTORSRecessed Installation - BR/BC36 Only Example for Common BrickMajestic Fireplaces BR/BC Series Installing Line For Gas Log7412944 Item/Model Number BR/BC SERIESMajestic Fireplaces BR/BC Series BR/BC36Majestic Fireplaces BR/BC Series Accessories7412944 Majestic Fireplaces BR/BC Series Chimney Components7412944 Majestic Fireplaces BR/BC Series Chimney Components cont. Canada7412944 B. Firegrate, Glass Doors, Outside Air System LIMITED WARRANTY & 30 YEAR PROTECTION PLAN7412944 C. Fan MotorCFM Corporation