Empire Comfort Systems VFSM-18-3, VFSV-16-3, VFSV-24-3 VFSM-18, 24, 30 Lighting Instructions

Page 15

VFSM-(18, 24, 30) LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus-

ing property damage, personal injury or loss of life.

A.

 

 

 

 

This appliance has a pilot which must be lighted by hand.

 

 

 

When lighting the pilot, follow these instructions exactly.

knob. Never use tools. If the knob will not push in or

B.

BEFORE LIGHTING smell all around the appliance area

turn by hand, don't try to repair it; call a qualified service

 

for gas. Be sure to smell next to the floor because some gas

technician. Force or attempted repair may result in a fire

 

is heavier than air and will settle on the floor.

or explosion.

 

WHAT TO DO IF YOU SMELL GAS

D. Do not use this appliance if any part has been under

 

 

• Do not try to light any appliance.

water. Immediately call a qualified service technician

 

 

• Do not touch any electrical switch;

to inspect the appliance and to replace any part of the

 

 

do not use any phone in your building.

control system and any gas control which has been under

 

 

• Immediately call your gas supplier from a neighbor's

water.

 

 

phone. Follow the gas supplier's instructions.

 

 

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information.

2.Make sure the manual shutoff valve is fully open.

3.This heater is equipped with an ignition device (piezo) which automatically lights the pilot.

4.Refer to Figure 15 for the location of the piezo ignitor and control knob. Push in gas control knob slightly and

turn

control knob clockwise

to

the OFF position.

 

 

NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow the instructions under ‘What To Do If You Smell Gas”. If you do not smell gas, go to the next step.

6.From OFF position, push in gas control knob slightly and

turn counterclockwise to the PILOT position. Push in and hold control knob for 5 seconds.

NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7.With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot is located on the right rear side of the heater, behind the middle log

and in front of the rear log. If piezo ignitor does not light the pilot, refer to “Match Lighting Instructions”.

8.Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas while the thermocouple is warming up.

9.Release the control knob.

* If the knob does not pop out when released, stop and immediately call your service technician or gas supplier.

*If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwise to OFF and wait 15 seconds. Repeat steps 6 through 9.

10.Push in control knob and turn to desired setting (1, 2, 3). The control knob must be set at either the low or high position, and the control knob will pop out when positioned correctly. Do not set the control knob at a position between pilot (1, 2, 3).

TO TURN OFF GAS TO APPLIANCE

1.Turn control knob clockwise to OFF position to completely shut off the heater.

18954-0-0705

Page 15

Image 15
Contents Installation Instructions Table of Contents Death Important Safety InformationDo not Tamper with Pilot Light Safety Carbon Monoxide Poisoning MAY Lead toLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction AccessoriesWater Vapor a BY-PRODUCT of Unvented Room Heaters General InformationClearances VFSV-16VFSR-16 Material Heat Resistant MaterialHood Heater in Fireplace Or Firebox Heat ResistantFireplace Preparation Combustible MaterialBefore Fully Installing the Appliance Installing AS a Vented ApplianceGAS Supply Operation INSTRUCTIONS/FLAME Appearance Placement of Glowing Embers and Lava RockVFSR-16, 18, 24, 30 Lighting Instructions What to do if YOU Smell GASPiezo Ignitor HI/LO Regulator Control Knob VFSV-16, 18, 24, 30 Lighting Instructions VFSM-18, 24, 30 Lighting Instructions Pilot Flame Characteristics Vfsr PilotVfsv and Vfsm Pilot Turn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingWiring VfsrVfsv Troubleshooting Index Part Description Number Parts ListParts View HOW to Order Repair Parts Service Notes Service Notes FAX

VFSV-30-3, VFSM -30-3, VFSR-30-3, VFSV-24-3, VFSR-24-3 specifications

Empire Comfort Systems offers a range of high-performance gas-fired vent-free space heaters, including the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models. These heaters are designed to provide effective, efficient, and environmentally friendly heating solutions for homes and businesses.

One of the key features of these models is their vent-free technology, which allows them to operate without the need for external venting. This design not only simplifies installation but also maximizes heat output in enclosed spaces, making them ideal for areas where traditional heating methods are impractical. The units are equipped with a safety pilot system that automatically shuts off the gas flow in case of a malfunction, ensuring safety for users.

The VFSM and VFSV series offer a variety of heating capacities, ranging from 16,000 to 30,000 BTUs, catering to different room sizes and heating requirements. The adjustable heat settings allow users to customize their heating experience based on their comfort needs. Additionally, the units feature a thermostat control option, which provides even greater ease of use and energy efficiency.

Energy efficiency is another hallmark of Empire’s vent-free heaters, as they utilize 99% of the gas consumed for heating. This high efficiency translates into lower energy bills for consumers. Furthermore, these heaters produce minimal emissions, making them an environmentally conscious choice for heating.

The VFSM and VFSV models are available in a range of stylish designs and finishes, allowing them to blend seamlessly with various home decors. Their compact sizes mean they can be installed in tight spaces or mounted on walls, optimizing room layouts without sacrificing heating performance.

Another notable characteristic is the option for remote control operation. This feature provides added convenience, allowing users to adjust settings from across the room. With their robust construction and user-friendly features, the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models stand out as reliable solutions for efficient heating needs, ensuring comfort during the cold months while prioritizing safety and environmental considerations.