Empire Comfort Systems VFSR-24-3, VFSV-16-3, VFSV-24-3, VFSV-18-3, VFSV-30-3 Cleaning and Servicing

Page 17

PILOT FLAME CHARACTERISTICS (continued)

Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot (Figure 21)

When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows:

1.Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench.

2.Blow air pressure through the holes indicated by the arrows. This will blow out foreign materials such as dust, lint and spider webs. Tighten nut B also by grasping nut A.

Warning: Never use needles, wires, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow.

Figure 21

CLEANING AND SERVICING

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting.

TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Refer to manual for correct log placement.

PERIODIC CLEANING – Refer to parts diagram for location of items discussed below.

Do not use cleaning fluid to clean logs or any part of heater.

Logs - brush with soft bristle brush or vacuum with brush attachment.

Remove loose particles and dust from the burner areas, controls, piezo covers and grate. Don’t remove media from inside burner box.

Inspect and clean burner air intake hole. Remove lint or particles with brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

ANNUAL CLEANING/INSPECTION – Refer to parts diagram for location of items discussed below.

Inspect and clean burner air intake hole. Remove lint or particles with vacuum or brush. Failure to keep air intake hole clean will result in sooting and poor combustion.

Inspect and clean all burner ports.

Inspect ODS pilot for operation and accumulation of lint at air intake holes.

Verify flame pattern and log placement for proper operation.

Verify smooth and responsive ignition of main burner.

Check level of ceramic media in burner. Burner should be full, up to the level of openings in burner top.

18954-0-0705

Page 17

Image 17
Contents Installation Instructions Table of Contents Do not Tamper with Pilot Light Safety Important Safety InformationCarbon Monoxide Poisoning MAY Lead to DeathLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction AccessoriesWater Vapor a BY-PRODUCT of Unvented Room Heaters General InformationVFSR-16 ClearancesVFSV-16 Hood Heater in Fireplace Or Firebox Heat Resistant MaterialHeat Resistant MaterialFireplace Preparation Combustible MaterialBefore Fully Installing the Appliance Installing AS a Vented ApplianceGAS Supply Operation INSTRUCTIONS/FLAME Appearance Placement of Glowing Embers and Lava RockPiezo Ignitor HI/LO Regulator Control Knob VFSR-16, 18, 24, 30 Lighting InstructionsWhat to do if YOU Smell GAS VFSV-16, 18, 24, 30 Lighting Instructions VFSM-18, 24, 30 Lighting Instructions Vfsv and Vfsm Pilot Pilot Flame CharacteristicsVfsr Pilot Turn OFF Heater and Allow to Cool Before Cleaning Cleaning and ServicingVfsv WiringVfsr Troubleshooting Index Part Description Number Parts ListParts View HOW to Order Repair Parts Service Notes Service Notes FAX

VFSV-30-3, VFSM -30-3, VFSR-30-3, VFSV-24-3, VFSR-24-3 specifications

Empire Comfort Systems offers a range of high-performance gas-fired vent-free space heaters, including the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models. These heaters are designed to provide effective, efficient, and environmentally friendly heating solutions for homes and businesses.

One of the key features of these models is their vent-free technology, which allows them to operate without the need for external venting. This design not only simplifies installation but also maximizes heat output in enclosed spaces, making them ideal for areas where traditional heating methods are impractical. The units are equipped with a safety pilot system that automatically shuts off the gas flow in case of a malfunction, ensuring safety for users.

The VFSM and VFSV series offer a variety of heating capacities, ranging from 16,000 to 30,000 BTUs, catering to different room sizes and heating requirements. The adjustable heat settings allow users to customize their heating experience based on their comfort needs. Additionally, the units feature a thermostat control option, which provides even greater ease of use and energy efficiency.

Energy efficiency is another hallmark of Empire’s vent-free heaters, as they utilize 99% of the gas consumed for heating. This high efficiency translates into lower energy bills for consumers. Furthermore, these heaters produce minimal emissions, making them an environmentally conscious choice for heating.

The VFSM and VFSV models are available in a range of stylish designs and finishes, allowing them to blend seamlessly with various home decors. Their compact sizes mean they can be installed in tight spaces or mounted on walls, optimizing room layouts without sacrificing heating performance.

Another notable characteristic is the option for remote control operation. This feature provides added convenience, allowing users to adjust settings from across the room. With their robust construction and user-friendly features, the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models stand out as reliable solutions for efficient heating needs, ensuring comfort during the cold months while prioritizing safety and environmental considerations.