Empire Comfort Systems Parts for VFSR & VFSM Models - Complete Parts List

Page 20

PARTS LIST

Attention: When ordering parts, it is very important that part number and description of part coincide.

 

Index

Part

Description

Index

Part

Description

 

No.

Number

 

No.

Number

 

 

 

 

COMMON PARTS

NS

14041

TUBING - PILOT REGULATOR TO PILOT

1

15425

REAR LOG SUPPORT (16)

 

 

- NAT

NS

11291

TUBING - VALVE TO BURNER

1

15426

REAR LOG SUPPORT (18)

NS

R-5668

IGNITOR WIRE

1

15427

REAR LOG SUPPORT (24)

NS

R-5910

SWITCH LOG ASSEMBLY (INCLUDES

1

15428

REAR LOG SUPPORT (30)

 

 

SWITCH AND WIRE)

2

11285

BURNER SUPPORT - LEFT (16)

 

 

NS

R-5757

OFF/ON SWITCH

2

11376

BURNER SUPPORT - LEFT (18,24,30)

NS

R-5699

WIRE HARNESS

3

P-200

ORIFICE FITTING

 

 

 

4

P-204

ORIFICE - LP (VFSR-16 VFSV-16)

 

 

VARIABLE SYSTEM

4

P-256

ORIFICE - NAT (VFSR-16 VFSV-16)

6

R-5170

PILOT LP

4

P-250

ORIFICE - LP (VFSR-18 VFSV-18 VFSM-18)

6

R-5171

PILOT NAT

4

P-203

ORIFICE - NAT (VFSM-18)

8

R-7063

PILOT REGULATOR (NAT ONLY)

4

P-243

ORIFICE - NAT (VFSR-18 VFSV-18)

10

11333

BURNER SUPPORT - RIGHT (16)

4

P-245

ORIFICE - LP (VFSR-24 VFSV-24 VFSM-24)

10

11308

BURNER SUPPORT - RIGHT (18,24,30)

4

P-244

ORIFICE - NAT (VFSR-24 VFSV-24 VFSM-24)

12

R-5672

GAS VALVE NATURAL

4

P-265

ORIFICE - LP (VFSR-30 VFSV-30 VFSM-30)

12

R5673

GAS VALVE LPG

4

P-209

ORIFICE - NAT (VFSM-30)

NS

11335

TUBING - VALVE TO PILOT-LPG

4

P-211

ORIFICE - NAT (VFSR-30 VFSV-30)

NS

14040

TUBING - VALVE TO PILOT REGULATOR

5

R-5676

AIR SHUTTER - NAT

 

 

- NAT

5

R-5675

AIR SHUTTER - LP

NS

14041

TUBING - PILOT REGULATOR TO PILOT

7

11833

PILOT SHIELD (NAT ONLY)

 

 

- NAT

NS

11291

TUBING - VALVE TO BURNER

9

12347

BURNER ASSEMBLY (16) NAT

NS

R-5797

REMOTE KIT

9

12348

BURNER ASSEMBLY (16) LPG

 

 

 

9

14033

BURNER ASSEMBLY (18)

 

 

MANUAL SYSTEM

9

14035

BURNER ASSEMBLY (24)

 

 

6

R-5170

PILOT LP

9

14037

BURNER ASSEMBLY (30)

6

R-5171

PILOT NAT

 

NS

12389

CERAMIC MEDIA

 

10

11481

BURNER SUPPORT - RIGHT

 

NS

15998

ROCK WOOL (16)

 

13

15414

REGULATOR MOUNTING BRACKET

 

NS

15999

ROCK WOOL (18)

 

14

R-2480

INLET REGULATOR - LP

 

NS

15970

ROCK WOOL (24,30)

 

14

R-2479

INLET REGULATOR - NAT

 

NS

11788

DECORATIVE ROCK (2 REQ’D)

 

15

R-2313

PIEZO IGNITOR

 

NS

R-2809

DAMPER CLAMP (INCLUDED IN HARD-

 

16

R-2783

CONTROL KNOB

 

 

 

WARE PACKAGE)

 

 

 

17

15416

VALVE BRACKET

 

 

 

 

 

 

 

MILLIVOLT SYSTEM

18

R-4499

GAS VALVE - LP

6

R-3624

PILOT NAT

18

R-4495

GAS VALVE - NAT

6

R-3623

PILOT LP

19

15494

COVER PLATE

8

R-7063

PILOT REGULATOR (NAT ONLY)

NS

R-5668

IGNITOR WIRE

10

11286

BURNER SUPPORT - RIGHT (16)

NS

15528

TUBING ASSEMBLY - INLET REGULATOR TO

10

11375

BURNER SUPPORT - RIGHT (18,24,30)

 

 

VALVE

NS

15529

TUBING - VALVE TO BURNER

11

R-4323

GAS VALVE NATURAL

NS

15530

TUBING - VALVE TO PILOT-LPG

11

R-4324

GAS VALVE LPG

NS

15531

TUBING - VALVE TO PILOT REGULATOR

 

NS

11292

TUBING - VALVE TO PILOT - LPG

 

 

 

- NAT

 

NS

14039

TUBING - VALVE TO PILOT REGULATOR

 

 

 

NS

15532

TUBING - PILOT REGULATOR TO PILOT

 

 

 

- NAT

 

 

 

 

 

- NAT

 

 

 

 

 

 

 

 

 

 

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Page 20

 

 

 

 

18954-0-0705

Image 20
Contents Installation Instructions Table of Contents Important Safety Information Do not Tamper with Pilot Light SafetyCarbon Monoxide Poisoning MAY Lead to DeathSafety Information for Users of LP-GAS LP-GAS Warning OdorAccessories IntroductionGeneral Information Water Vapor a BY-PRODUCT of Unvented Room HeatersVFSR-16 ClearancesVFSV-16 Heat Resistant Material Hood Heater in Fireplace Or FireboxHeat Resistant MaterialCombustible Material Fireplace PreparationInstalling AS a Vented Appliance Before Fully Installing the ApplianceGAS Supply Placement of Glowing Embers and Lava Rock Operation INSTRUCTIONS/FLAME AppearancePiezo Ignitor HI/LO Regulator Control Knob VFSR-16, 18, 24, 30 Lighting InstructionsWhat to do if YOU Smell GAS VFSV-16, 18, 24, 30 Lighting Instructions VFSM-18, 24, 30 Lighting Instructions Vfsv and Vfsm Pilot Pilot Flame CharacteristicsVfsr Pilot Cleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningVfsv WiringVfsr Troubleshooting Parts List Index Part Description NumberParts View HOW to Order Repair Parts Service Notes Service Notes FAX

VFSV-30-3, VFSM -30-3, VFSR-30-3, VFSV-24-3, VFSR-24-3 specifications

Empire Comfort Systems offers a range of high-performance gas-fired vent-free space heaters, including the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models. These heaters are designed to provide effective, efficient, and environmentally friendly heating solutions for homes and businesses.

One of the key features of these models is their vent-free technology, which allows them to operate without the need for external venting. This design not only simplifies installation but also maximizes heat output in enclosed spaces, making them ideal for areas where traditional heating methods are impractical. The units are equipped with a safety pilot system that automatically shuts off the gas flow in case of a malfunction, ensuring safety for users.

The VFSM and VFSV series offer a variety of heating capacities, ranging from 16,000 to 30,000 BTUs, catering to different room sizes and heating requirements. The adjustable heat settings allow users to customize their heating experience based on their comfort needs. Additionally, the units feature a thermostat control option, which provides even greater ease of use and energy efficiency.

Energy efficiency is another hallmark of Empire’s vent-free heaters, as they utilize 99% of the gas consumed for heating. This high efficiency translates into lower energy bills for consumers. Furthermore, these heaters produce minimal emissions, making them an environmentally conscious choice for heating.

The VFSM and VFSV models are available in a range of stylish designs and finishes, allowing them to blend seamlessly with various home decors. Their compact sizes mean they can be installed in tight spaces or mounted on walls, optimizing room layouts without sacrificing heating performance.

Another notable characteristic is the option for remote control operation. This feature provides added convenience, allowing users to adjust settings from across the room. With their robust construction and user-friendly features, the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models stand out as reliable solutions for efficient heating needs, ensuring comfort during the cold months while prioritizing safety and environmental considerations.