SR-10T CLEARANCES
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm). Maximum horizontal extension of projection above the appliance 12 inches (305mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
24 " MIN (610mm)
14" MIN
(356mm)6 " MIN6 "MIN
(152mm)(152mm)
2 " MIN (51mm)
Figure 3 (SR-10T)
12" MAX (305mm)
24 " MIN (610mm)
14" MIN | 0" (0mm) CLEARANCE |
(356mm) | TO REAR WALL |
2 " MIN (51mm)
Figure 4 (SR-10T)
Page 8 |