Empire Products SR-30T-3, SR-18T-3, SR-10T-3 Wall Mount Installation, On Sheet Rock Wall

Page 10

WALL MOUNT INSTALLATION

Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters.

1.Remove lower louver from casing assembly (2 screws).

2.Remove reflector from casing assembly (2 screws).

3.Remove upper louver from casing assembly (2 screws).

1113/16"

(300mm)

 

 

7 13/16"

1 3/32"

 

(198mm)

 

 

 

2"

2"

(28mm)

(51)

(51)

18 7/8"

(479mm)22" (559mm)

41/32"

(102mm)

2"MIN (51mm)

Figure 7 (SR-10T)

18"

(457mm)

2"

14"

2"

(51)

(356mm)

(51)

13/32

(28mm)

18 7/8"

22"

(479mm)

(559mm)

 

 

2 1/32 (52mm)

4 1/32"

2" (51mm)

(102mm) MIN

 

Figure 8 (SR-18T)

241/8"

(613mm)

2"

20 1/8"

2"

(511mm)

(51)

(51)

 

 

13/32"

(28mm)

18 7/8"

22"

(479mm)

(559mm)

4 1/32

2 1/32" (52mm)

(102mm)

 

MIN

2" (51mm) MIN

Figure 9 (SR-30T)

On Solid Wall

1.After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall.

2.Mount heater onto the (4) screwheads and complete tightening screwheads into the wall.

Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield.

a.When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.

b.When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.

3.Connect the gas line.

On Sheet Rock Wall

1.After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall.

2.Insert (4) plastic expansion anchors provided into the holes.

3.Tighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads to the plastic expansion anchors, leave a 1/8" (3mm) gap between screwheads and plastic expansion anchors.

Page 10

16009-1-0504

Image 10
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionWater Vapor a BY-PRODUCT of Unvented Room Heaters Unusually Tight ConstructionGas Supply Pressure Testing of the Gas Supply SystemGAS Supply Checking Manifold PressureSR-10T Clearances SR-10TSR-18T Clearances SR-30T ClearancesWall Mount Installation On Sheet Rock WallOptional Floor Stand Installation Installation on Rugs and TileFor Your Safety Read Before Lighting Lighting InstructionsMain Burner Flame Characteristics Oxygen Depletion Sensor Pilot Figure Pilot Flame CharacteristicsThermostat Operation Main Burner OperationAppliance Maintenance HOW to Order Repair Parts TroubleshootingParts List SR-18T Parts View Parts View SR-30T Optional Blower Installation Isntructions Excessive Blower Wheel NoiseOptional Blower Installation Isntructions Service Notes Mail info@empirecomfort.com