SR-18T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

 

36" (914mm) MIN

6" (152mm)

6" (152mm)

MIN

MIN

 

2" (51mm)

MIN

Figure 5 (SR-18T)

SR-30T CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

 

36" (914mm) MIN

8"

8"

(203mm)

(203mm)

MIN

MIN

2"

(51mm)

MIN

Figure 6 (SR-30T)

16009-1-0504

Page 9

Image 9
Contents Installation Instructions Table of Contents Important Safety Information LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersGAS Supply Pressure Testing of the Gas Supply SystemGas Supply Checking Manifold PressureSR-10T SR-10T ClearancesSR-30T Clearances SR-18T ClearancesOn Sheet Rock Wall Wall Mount InstallationInstallation on Rugs and Tile Optional Floor Stand InstallationLighting Instructions For Your Safety Read Before LightingMain Burner Flame Characteristics Thermostat Operation Pilot Flame CharacteristicsOxygen Depletion Sensor Pilot Figure Main Burner OperationAppliance Maintenance Troubleshooting HOW to Order Repair PartsParts List SR-18T Parts View Parts View SR-30T Excessive Blower Wheel Noise Optional Blower Installation IsntructionsOptional Blower Installation Isntructions Service Notes Mail info@empirecomfort.com