Louisville Tin and Stove VCR352A-H Table of Contents, Read Carefully Before Installing Unit

Page 2

TABLE OF CONTENTS

SPECIFICATIONS……………………….

2

INTRODUCTION………………………..

3

VENTING………………………………...

3 ,4

GASSUPPLY…………………………….

5

LOCATION & SPECIAL PRECAUTIONS

5

COMBUSTION & VENTILATION AIR....

6

CLEARANCES…………………………..

7

DRAFTDIVERTER……………………..

7

DOORKNOB……………………………

7

PILOT ADJUSTMENT………………….

8

RADIANTS & GLASS PANELS………..

8

BURNER ORIFICE & ORIFICE CHART

8

PROPER BURNER FLAME.............…………. 9

MAINTENANCE…………………………....... 9

LIGHTING INSTRUCTIONS……………........ 10

TROUBLE SHOOTING CHART…………

11,12

BLOWERINSTRUCTIONS………………

13

TSK WALL STAT KIT

14

PARTS DRAWING………………………..

15

PARTSPRICELIST……………………….

16

WARRANTY………………………………

18

READ CAREFULLY BEFORE INSTALLING UNIT

These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before planning or making the installation be sure it complies with all phases of the local heating code. (Or, in the absence of local codes, with the latest edition of National Fuel Gas Code, ANSI.Z223.1, or CAN1-B149).

The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the latest edition of National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code CSA-C22.1.

All of the ANSI and NFPA standards referred to in these installation instructions are the ones that were applicable at the time the design of this appliance was certified. The ANSI standards are available from the American Gas Association, 1515 Wilson Blvd., Arlington, VA. 22209.

The NFPA standards are available from the national Fire Protection Association, 60 Batterymarch Street, Boston, Massachusetts 02110.

Canadian standards are available from International Approval Services, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.

The design of this appliance was certified to comply with ANSI Z21.11.1 vented room heaters and CAN1-2.1-M86.

Installer must leave these instructions with the consumer, have them complete, and return the warranty card.

ROOM HEATER SPECIFICATIONS

Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is correct and that the room heater is equipped for the type gas you intend to use.

SPECIFICATIONS

TYPE

 

 

CONTROL

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBERS

 

 

 

 

 

 

 

 

 

 

 

CLOSED FRONT

THERMOSTAT BULB

 

NATURAL

 

 

VC201A-H

VC351A-H

 

 

VC501A-H

 

 

VC701A-H

CLOSED FRONT

THERMOSTAT BULB

 

L.P.

 

 

VC202A-H

VC352A-H

 

 

VC502A-H

 

 

VC702A-H

RADIANT FRONT

THERMOSTAT BULB

 

NATURAL

 

 

N/A

VCR351A-H

 

VCR501A-H

 

 

VCR701A-H

RADIANT FRONT

THERMOSTAT BULB

 

L.P.

 

 

N/A

VCR352A-H

 

VCR502A-H

 

 

VCR702A-H

HEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20”

 

26”

 

 

26”

 

 

30”

WIDTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24”

 

30”

 

 

30”

 

 

36”

DEPTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15-1/4”

 

15-1/4

 

 

19-1/4”

 

 

19-1/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT (BTU/HR.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20,000

 

 

 

35,000

 

 

 

50,000

 

 

 

 

 

70,000

 

 

 

 

 

GAS INLET/OUTLET SIZE

 

 

 

 

 

 

 

 

 

 

 

 

1/2X3/8”

 

1/2X3/8”

 

1/2X3/8”

 

 

1/2X3/8”

VENT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3”

 

4”

 

 

4”

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CENTER OF VENT TO FLOOR

 

 

 

 

 

 

 

 

 

 

 

 

16-1/2”

 

21-1/2”

 

21-1/2”

 

 

25-1/2”

NUMBER OF RADIANTS (“VCR” SERIES)

 

 

 

 

 

 

 

 

 

 

 

 

N/A

5

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

NUMBER OF RADIANT GLASS (“VCR” SERIES)

 

 

N/A

2

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROX. SHIPPING WEIGHT (“VC” SERIES)

 

 

55 LBS.

84 LBS.

 

112 LBS.

 

 

138 LBS.

APPROX. SHIPPING WEIGHT (“VCR” SERIES)

 

 

N/A

96 LBS.

 

124 LBS.

 

 

150 LBS.

*OPTIONAL BLOWER MODEL

 

 

 

 

 

 

 

 

 

 

 

 

N/A

CHB-3

 

CHB-3

 

 

CHB-3

*Blowers also available factory mounted on 50M Btu units. All 70M Btu units come with blower mounted only.

Page 2

Image 2
Contents Natural GAS This Unit is not to be Installed in Mobile HomesWhat to do if YOU Smell GAS VCR351A-H VCR501A-H VCR701A-H Propane GASRoom Heater Specifications Table of ContentsRead Carefully Before Installing Unit Specifications Type Control GAS Model NumbersPossible Causes Corrective Action IntroductionVenting Connecting the Vent Into AN Existing Chimney Unsafe RecommendedLocation and Speical Precautions GAS SupplyCombustion and Ventilation AIR UL Listed Vent Cap UL Listed Gas Vent OpeningClearances Draft DiverterDoor Knob Ment Pilot AdjustmentPilot Flame Adjust Radiants and Glass PanelsMaintenance Cleaning of Combustion ChamberFor Your Safety Read Before Lighting What to do if YOU Smell GASTrouble Shooting Chart for qualified serviceman Main Burner Symptom Possible Causes Corrective ActionTrouble Shooting Chart Automatic Pilot & Valve If any part of the original wire as suppied TSK Wall Stat KIT Optional Models Included REV /05March Revised 01/05 *2 Required Tampering is Dangerous Critical Safety Points to RememberYour GAS Control and Pilot Light System If YOU Smell GAS, DON’T Light ITLimited Warranty