Jotul GI 425 DV manual Connecting the Gas Supply, Gas Supply Requirements, Gas Pressure

Page 14

Connecting the Gas Supply

Gas Supply Requirements

ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR CAN-B149.

NOTE: INSTALL THE OPTIONAL BLOWER BEFORE PLUMBING THE GAS LINE TO THE VALVE.

THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS.

Shutoff Valve

All codes require a gas shutoff valve (gas cock) and union to be installed in the supply line and in the same room as the appliance. This allows for the disconnection of the fireplace for servicing and maintenance. See Fig. 9.

A T-HANDLE GAS SHUTOFF VALVE IS REQUIRED IN MASSACHUSETTS IN COMPLIANCE WITH CODE 248CMR.

The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of the system at test pressures in excess of 1/2 psig. For pressures lower than 1/2 psig, isolate the gas supply by closing the manual shutoff valve.

Control Valve Connection

The gas supply line connection is made to the left side of the valve. The gas supply line should be a minimum 3/8" diameter, or the appropriate size to provide sufficient gas pressure to the valve regard- less of the input setting.

The use of flexible gas appliance connectors is acceptable in many areas in the U.S. In Canada, methods vary depending on local code. If local codes permit, use flexible gas line for ease of installation and service. For those locales where flexible gas lines are not permitted, use the 3/8” iron fitting to make the connection at the left side of the Control Valve. See Figures 9 and 10.

Secure all joints tightly using appropriate tools and sealing compounds (for propane units, be sure to use compounds that are propane resistant). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks.

Leak test:

Mix a 50-50 solution of water and dish soap.

Light appliance- see lighting instructions on page 23 of this manual or on the fireplace’s rating plate.

Brush or spray all joints and connections with the soapy water solution.

If bubbles appear at any connection or seam or a gas odor is detected, immediately turn gas control knob to the OFF position.

Tighten or reconnect the leaking joint and retest for any gas leaks.

Figure 9. Gas supply line fittings.

Gas Pressure

Proper gas pressure provides a consistent flow of gas to the appliance and is instrumental in checking for gas leaks. The gas control valve on the fireplace is equipped with pressure test points for gauge connections. The gauge connections are located on the front of the valve under the On/Off/ Pilot knob. Gauge connections are identified by:

IN/E for inlet or supply pressure (the amount of gas coming to the valve.)

OUT/A for manifold pressure (the amount of gas that is coming out of the valve to the burner.)

E A

Figure 10. Pressure test point as located on the front of the valve.

14

Image 14
Contents Jøtul GI 425 DV Camden Classic Welcome to Jøtul Table of Contents Jøtul GI 425 Camden Direct Vent Gas Fireplace AccessoriesSpecifications Test StandardsGeneral Information Electrical Hazard Safety InformationInstallation Requirements GI 425 DV dimensions Minimum Fireplace RequirementsOptional Lattice Classic Surround Clearance RequirementsStandard Classic Surround Optional Wide SurroundHearth Requirements Mantel and Trim ClearanceMasonry Fireplace Installation Vent GuidelinesVenting through a Masonry Fireplace FlexintakePrefabricated Fireplace Installation Modification Steps23234 Gas Pressure Connecting the Gas SupplyGas Supply Requirements High Altitude Adjustment Excessive gas pressureFuel Conversion Fuel Conversion ProcedureConversion Kit Contents Tools requiredApply the Conversion Labels Adjust the Air Shutter See FigChange the Regulator See Fig Wall Thermostat Installation Remote ControlBrick Panel Assembly Panel installation orderLogset Assembly Logset PartsBlower Power Requirement Surround AssemblyBlower Installation Flame Appearance / Air Shutter Adjustment System CheckVariable Vent Restriction Air Shutter AdjustmentAir Inlet Settings Operation GI425 Controls Gas Valve and RegulatorBlower Conrol Blower FunctionBurner Control Glass Care MaintenanceAnnual Cleaning Vent SystemGlass Panel or Gasket Replacement Gasket ReplacementJøtul GI 425 DV Camden Classic Lllustrated Parts Breakdown 22 12Jøtul GI 425 DV Camden Parts List Jøtul North America Hutcherson Dr Gorham, ME 04038 207WAS Fireplace CON Lighting Instructions Control ValveJøtul AS Jøtul North America

GI 425 DV specifications

The Jotul GI 425 DV is a beautifully designed gas stove that blends traditional aesthetics with modern technology, making it a popular choice for homeowners seeking warmth and style. This versatile unit is part of the Jotul brand’s renowned range of gas appliances, allowing users to enjoy the charm of a fire without the hassle of wood.

One of the standout features of the Jotul GI 425 DV is its striking design. It is available in various finishes, including a classic black or a more contemporary white enamel, enabling it to fit seamlessly into a variety of interior decor styles. The large glass door provides a clear view of the flame, enhancing the ambiance of any room while also allowing for easy monitoring of the fire.

In terms of performance, the Jotul GI 425 DV is engineered for efficiency. The stove utilizes a Direct Vent system, which ensures that air from outside is drawn in for combustion, while exhaust gases are expelled outside. This helps to maintain a comfortable indoor environment without compromising air quality. Additionally, the stove offers adjustable flame height and heat output, allowing users to tailor the warmth to their needs.

The appliance is equipped with advanced technology, such as a standing pilot light and an igniter, which ensures quick and reliable starts, even during colder months. The internal heat exchanger distributes warmth evenly throughout the room, enhancing heating efficiency. This model also features a remote control option, enabling users to adjust settings from the comfort of their sofa.

The Jotul GI 425 DV is designed to meet modern environmental standards, incorporating a low-emission gas burner system. This means it produces fewer pollutants while providing the same amount of heat, making it a more eco-friendly choice compared to traditional wood stoves.

Another important characteristic of the Jotul GI 425 DV is its safety features. With a robust build and advanced safety shut-off systems, users can enjoy peace of mind while using the stove, knowing that their home is safe.

In conclusion, the Jotul GI 425 DV gas stove combines elegant design, cutting-edge technology, and efficient performance. With its customizable features and environmental considerations, it is an ideal choice for anyone looking to add both warmth and style to their living space while benefiting from the convenience of gas heating.