Jotul GI 425 DV manual Vent Guidelines, Masonry Fireplace Installation

Page 10

Vent Guidelines

All vent components must be installed in accor- dance with the listing terms and manufacturer’s instructions.

Vent Height: Measured from the top of the insert to the top of the termination cap.

Minimum: no less than 10'

Maximum: no greater than 35'. See figures 9 and 10.

The minimum vent height above the roof or adjacent walls is specified by building codes. As a general guide, follow the Gas Vent Rule on page 12.

HORIZONTAL RUNS ARE NOT PERMITTED ANY- WHERE IN THE VENTING SYSTEM.

Venting liners used on this appliance may not be less than 3” in diameter or greater than 3” in diameter.

Any unused flue or masonry enclosure can be used as a passageway for venting provided the flue is relined using 3” Listed flexible gas liner.

The remaining space around the liner in a ma- sonry or zero-clearance flue CANNOT be used to vent any other appliance.

Flexible liner components may not be exposed in any living space.

Installation of any components not manufactured or approved by Jøtul or failure to meet all clear- ance requirements will void all warranties and could result in property damage, bodily injury, or serious fire.

Never modify any venting component, or use any damaged venting product.

THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD- ING, AND NEVER ATTACHED TO A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING APPLI- ANCE.

Variable Vent Restriction: See the System Check section on pages 22-23 for specific instructions.

IMPORTANT NOTICE:

THE USE OF AN EXISTING CHIMNEY AS AN AIR INTAKE IS NOT COVERED UN- DER THE ANSI Z21.88-1999-CSA 2.33-

M99 TEST METHODS AND RESULTING ITS/WHI PRODUCT CERTIFICATION. THE CODE AUTHORITY HAVING JURIS- DICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLA- TION METHOD.

Masonry Fireplace Installation

When installing a GI425 DV Camden gas insert into a masonry fireplace the insert will be vented through dual 3” flexible gas aluminum liners.

This co-linear installation includes a pair of 3” flex ducts that run from the insert completely through the existing chimney to the termination cap.

One liner is attached to the Exhaust Outlet on the back of the unit and will carry the exhaust gases to the outside of the house. This exhaust liner must be directly connected to the unit and run the full length of the chimney. See figure 7.

The other 3” liner will be attached to the Air

Intake Collar on the back of the unit to provide fresh air for combustion. The Intake Collar is labeled for easy identification. The liner must extend a mini- mum of 6’ off the back of the unit and extend through the damper area of the fireplace into the tile liner of the chimney. This liner can also extend the full length of the chimney and connect to the termination cap.

IMPORTANT

If the intake flex does not extend the full length of the chimney, forming a direct connection between the unit and the termination cap, A METAL BLOCK OFF PLATE MUST BE INSTALLED to seal the air intake from room air. Normally this sealing plate will be installed within the existing fireplace damper area. See figure 7. The sealing plate is not necessary if a direct connection is made between the cap and the fireplace.

WARNING! Avoid cross venting the insert. Before installation, label both ends of the exhaust flex pipe to ensure connection to the appropriate collars on the fireplace unit and vent termination cap.

CANADA REQUIREMENT: Both the Intake and the Exhaust liners must extend the full length of the chimney and be securely connected to both the unit and the termina- tion kit.

If the fireplace has been modified to accom- modate installation, use anchors or masonry nails to attach the metal Fireplace Conver- sion Notice Plate supplied with this unit to the back wall of the masonry fireplace firebox where it will be readily seen should the insert be removed.

10

Image 10
Contents Jøtul GI 425 DV Camden Classic Welcome to Jøtul Table of Contents Jøtul GI 425 Camden Direct Vent Gas Fireplace AccessoriesSpecifications Test StandardsGeneral Information Installation Requirements Safety InformationElectrical Hazard GI 425 DV dimensions Minimum Fireplace RequirementsOptional Lattice Classic Surround Clearance RequirementsStandard Classic Surround Optional Wide SurroundHearth Requirements Mantel and Trim ClearanceMasonry Fireplace Installation Vent GuidelinesVenting through a Masonry Fireplace FlexintakePrefabricated Fireplace Installation Modification Steps23234 Gas Supply Requirements Connecting the Gas SupplyGas Pressure High Altitude Adjustment Excessive gas pressureFuel Conversion Fuel Conversion ProcedureConversion Kit Contents Tools requiredChange the Regulator See Fig Adjust the Air Shutter See FigApply the Conversion Labels Wall Thermostat Installation Remote ControlBrick Panel Assembly Panel installation orderLogset Assembly Logset PartsBlower Installation Surround AssemblyBlower Power Requirement Flame Appearance / Air Shutter Adjustment System CheckAir Inlet Settings Air Shutter AdjustmentVariable Vent Restriction Operation GI425 Controls Gas Valve and RegulatorBurner Control Blower FunctionBlower Conrol Glass Care MaintenanceAnnual Cleaning Vent SystemGlass Panel or Gasket Replacement Gasket ReplacementJøtul GI 425 DV Camden Classic Lllustrated Parts Breakdown 22 12Jøtul GI 425 DV Camden Parts List Jøtul North America Hutcherson Dr Gorham, ME 04038 207WAS Fireplace CON Lighting Instructions Control ValveJøtul AS Jøtul North America

GI 425 DV specifications

The Jotul GI 425 DV is a beautifully designed gas stove that blends traditional aesthetics with modern technology, making it a popular choice for homeowners seeking warmth and style. This versatile unit is part of the Jotul brand’s renowned range of gas appliances, allowing users to enjoy the charm of a fire without the hassle of wood.

One of the standout features of the Jotul GI 425 DV is its striking design. It is available in various finishes, including a classic black or a more contemporary white enamel, enabling it to fit seamlessly into a variety of interior decor styles. The large glass door provides a clear view of the flame, enhancing the ambiance of any room while also allowing for easy monitoring of the fire.

In terms of performance, the Jotul GI 425 DV is engineered for efficiency. The stove utilizes a Direct Vent system, which ensures that air from outside is drawn in for combustion, while exhaust gases are expelled outside. This helps to maintain a comfortable indoor environment without compromising air quality. Additionally, the stove offers adjustable flame height and heat output, allowing users to tailor the warmth to their needs.

The appliance is equipped with advanced technology, such as a standing pilot light and an igniter, which ensures quick and reliable starts, even during colder months. The internal heat exchanger distributes warmth evenly throughout the room, enhancing heating efficiency. This model also features a remote control option, enabling users to adjust settings from the comfort of their sofa.

The Jotul GI 425 DV is designed to meet modern environmental standards, incorporating a low-emission gas burner system. This means it produces fewer pollutants while providing the same amount of heat, making it a more eco-friendly choice compared to traditional wood stoves.

Another important characteristic of the Jotul GI 425 DV is its safety features. With a robust build and advanced safety shut-off systems, users can enjoy peace of mind while using the stove, knowing that their home is safe.

In conclusion, the Jotul GI 425 DV gas stove combines elegant design, cutting-edge technology, and efficient performance. With its customizable features and environmental considerations, it is an ideal choice for anyone looking to add both warmth and style to their living space while benefiting from the convenience of gas heating.