Jotul GI 425 DV manual General Information

Page 5

General Information

IMPORTANT:

SAVE THESE INSTRUCTIONS.

THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE.

1.The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

2.This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulat- ing air passageways of the appliance be kept clean.

`S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

3.The installation must conform to local codes. Your local Jøtul authorized dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector or authority having jurisdiction to determine what regulations apply in your area.

In the absence of local codes, the installation requirements must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.

Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

4.DO NOT OPERATE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER.

Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

5.Do not operate the fireplace with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Pour utilisation avec les portes en verre cerifiers aved l’appareil seulemend ou. Ne pas utiliser avec des portes on verre.

6.Notify your insurance company before proceding with installation of this fireplace.

5

Image 5
Contents Jøtul GI 425 DV Camden Classic Welcome to Jøtul Table of Contents Specifications AccessoriesJøtul GI 425 Camden Direct Vent Gas Fireplace Test StandardsGeneral Information Electrical Hazard Safety InformationInstallation Requirements Minimum Fireplace Requirements GI 425 DV dimensionsStandard Classic Surround Clearance RequirementsOptional Lattice Classic Surround Optional Wide SurroundMantel and Trim Clearance Hearth RequirementsVent Guidelines Masonry Fireplace InstallationFlexintake Venting through a Masonry FireplaceModification Steps Prefabricated Fireplace Installation23234 Gas Pressure Connecting the Gas SupplyGas Supply Requirements Excessive gas pressure High Altitude AdjustmentConversion Kit Contents Fuel Conversion ProcedureFuel Conversion Tools requiredApply the Conversion Labels Adjust the Air Shutter See FigChange the Regulator See Fig Remote Control Wall Thermostat InstallationPanel installation order Brick Panel AssemblyLogset Parts Logset AssemblyBlower Power Requirement Surround AssemblyBlower Installation System Check Flame Appearance / Air Shutter AdjustmentVariable Vent Restriction Air Shutter AdjustmentAir Inlet Settings GI425 Controls Gas Valve and Regulator OperationBlower Conrol Blower FunctionBurner Control Annual Cleaning MaintenanceGlass Care Vent SystemGasket Replacement Glass Panel or Gasket Replacement22 12 Jøtul GI 425 DV Camden Classic Lllustrated Parts BreakdownJøtul North America Hutcherson Dr Gorham, ME 04038 207 Jøtul GI 425 DV Camden Parts ListWAS Fireplace CON Control Valve Lighting InstructionsJøtul North America Jøtul AS

GI 425 DV specifications

The Jotul GI 425 DV is a beautifully designed gas stove that blends traditional aesthetics with modern technology, making it a popular choice for homeowners seeking warmth and style. This versatile unit is part of the Jotul brand’s renowned range of gas appliances, allowing users to enjoy the charm of a fire without the hassle of wood.

One of the standout features of the Jotul GI 425 DV is its striking design. It is available in various finishes, including a classic black or a more contemporary white enamel, enabling it to fit seamlessly into a variety of interior decor styles. The large glass door provides a clear view of the flame, enhancing the ambiance of any room while also allowing for easy monitoring of the fire.

In terms of performance, the Jotul GI 425 DV is engineered for efficiency. The stove utilizes a Direct Vent system, which ensures that air from outside is drawn in for combustion, while exhaust gases are expelled outside. This helps to maintain a comfortable indoor environment without compromising air quality. Additionally, the stove offers adjustable flame height and heat output, allowing users to tailor the warmth to their needs.

The appliance is equipped with advanced technology, such as a standing pilot light and an igniter, which ensures quick and reliable starts, even during colder months. The internal heat exchanger distributes warmth evenly throughout the room, enhancing heating efficiency. This model also features a remote control option, enabling users to adjust settings from the comfort of their sofa.

The Jotul GI 425 DV is designed to meet modern environmental standards, incorporating a low-emission gas burner system. This means it produces fewer pollutants while providing the same amount of heat, making it a more eco-friendly choice compared to traditional wood stoves.

Another important characteristic of the Jotul GI 425 DV is its safety features. With a robust build and advanced safety shut-off systems, users can enjoy peace of mind while using the stove, knowing that their home is safe.

In conclusion, the Jotul GI 425 DV gas stove combines elegant design, cutting-edge technology, and efficient performance. With its customizable features and environmental considerations, it is an ideal choice for anyone looking to add both warmth and style to their living space while benefiting from the convenience of gas heating.