CONDENSING UNIT SPECIFICATIONS

GSX130[36-60][3,4]* *

 

GSX130363A*

GSX130483A*

GSX130484A*

GSX130603A*

GSX130604A*

 

 

 

 

 

 

 

 

Cooling Capacity, BTUH

36,000

48,000

48,000

60,000

60,000

 

Decibels

74

76

76

77

77

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

R.L. Amps

10.40

13.1

6.1

15.9

7.1

 

L.R. Amps

73.0

83.1

41.0

110.0

52.0

 

Type

Scroll

Scroll

Scroll

Scroll

Scroll

 

Condenser Fan Motor

 

 

 

 

 

 

Horsepower

1/6

1/4

1/4

1/4

1/4

 

F.L. Amps

1.10

1.50

0.80

1.50

0.80

 

 

 

 

 

 

 

 

Refrigerant System

 

 

 

 

 

 

Liquid Line, Inches O.D.*

3/8"

3/8"

3/8"

3/8"

3/8"

 

Suction Line, Inches O.D.*

7/8"

1 1/8"

1 1/8"

1 1/8"

1 1/8"

 

Liquid Valve Connection, Inches O.D.*

3/8"

3/8"

3/8"

3/8"

3/8"

 

Suction Valve Connection, Inches O.D.* 3

3/4" 3

7/8" 4

7/8" 4

7/8" 4

7/8" 4

 

Refrigerant Charge

92.0

128.0

128.0

125.0

125.0

 

Piston Size

0.068

0.080

0.080

0.086

0.086

 

Power Supply

208/230-60-3

208/230-60-3

460-60-3

208/230-60-3

460-60-3

 

Minimum Circuit Ampacity(1)

14.1

17.9

8.4

21.4

9.7

 

Maximum Overcurrent Device(2)

20

30

15

35

15

 

Min / Max Volts

197 / 253

197 / 253

414 / 506

197 / 253

414 / 506

 

 

 

 

 

 

 

 

Electrical Conduit Size

 

 

 

 

 

 

Power Supply(Inches)

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

 

Approximate Shipping Weight

196

190

189

197

196

 

(1)Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.

(3)Installer must supply a 3/4" to 7/8" adapter for suction line connections.

(4)Installer must supply a 7/8" to 1 1/8" adapter for suction line connections.

NOTES:

*Always check the S&R plate for electrical data on the unit being installed.

*Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.

*Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

*Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

9

Page 9
Image 9
Goodman Mfg service manual GSX13036-603,4