MODEL: GSX130301B* / CA*F3030*6B*

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

95

 

 

 

105

 

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

 

63

67

71

 

 

 

 

 

MBh

25.8

26.4

 

28.2

30.1

25.2

25.8

 

27.5

29.4

24.6

25.1

 

26.9

28.7

24.0

24.5

 

26.2

28.0

22.8

23.3

24.9

26.6

21.1

 

21.6

23.1

24.7

 

 

 

 

 

S/T

0.86

0.81

0.66

0.49

0.90

0.84

0.68

0.51

0.92

0.86

0.70

0.52

0.95

0.89

 

0.72

0.54

0.98

0.92

0.75

0.56

0.99

 

0.93

0.76

0.57

 

 

 

 

875

Delta T

23

22

20

16

24

23

20

16

24

23

20

16

24

23

 

20

16

24

23

20

16

22

 

21

18

15

 

 

 

 

KW

1.97

2.01

2.07

2.13

2.11

2.15

2.22

2.29

2.24

2.28

2.35

2.43

2.35

2.40

 

2.47

2.55

2.44

2.49

2.57

2.66

2.52

 

2.58

2.66

2.75

 

 

 

 

 

AMPS

7.0

7.1

7.3

7.6

7.5

7.7

7.9

8.2

8.2

8.4

8.6

9.0

8.7

8.9

 

9.2

9.6

9.3

9.5

9.8

10.2

9.8

 

10.1

10.4

10.8

 

 

 

 

 

HI PR

233

250

264

276

261

281

297

310

297

320

338

352

338

364

 

384

401

381

410

432

451

420

 

452

478

498

 

 

 

 

 

LO PR

104

111

121

129

110

117

128

136

114

122

133

142

120

128

 

140

149

126

134

146

156

130

 

139

151

161

 

 

 

 

 

MBh

28.0

28.6

30.5

32.6

27.3

27.9

29.8

31.9

26.7

27.2

29.1

31.1

26.0

26.6

 

28.4

30.4

24.7

25.3

27.0

28.8

22.9

 

23.4

25.0

26.7

 

 

 

 

 

S/T

0.90

0.84

0.68

0.51

0.93

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.98

0.92

 

0.75

0.56

1.00

0.96

0.78

0.58

1.00

 

0.96

0.78

0.59

 

 

80

 

1000

Delta T

23

22

19

15

23

22

19

16

23

22

19

16

23

23

 

20

16

23

22

19

15

21

 

21

18

14

 

 

 

KW

2.01

2.05

2.12

2.18

2.16

2.20

2.27

2.34

2.29

2.34

2.41

2.49

2.40

2.46

 

2.53

2.61

2.50

2.56

2.64

2.72

2.59

 

2.64

2.73

2.82

 

 

 

 

 

AMPS

7.1

7.3

7.6

7.8

7.7

7.9

8.2

8.5

8.4

8.6

8.9

9.2

9.0

9.2

 

9.5

9.9

9.6

9.8

10.1

10.5

10.1

 

10.4

10.7

11.1

 

 

 

 

 

HI PR

240

258

273

284

269

290

306

319

306

330

348

363

349

375

 

396

413

392

422

446

465

433

 

466

493

514

 

 

 

 

 

LO PR

107

114

125

133

114

121

132

140

118

126

137

146

124

132

 

144

153

130

138

151

161

134

 

143

156

166

 

 

 

 

 

MBh

28.8

29.4

31.4

33.6

28.1

28.7

30.7

32.8

27.5

28.1

30.0

32.1

26.8

27.4

 

29.3

31.3

25.5

26.0

27.8

29.7

23.6

 

24.1

25.7

27.5

 

 

 

 

 

S/T

0.94

0.88

0.72

0.54

1.00

0.91

0.74

0.56

1.00

0.94

0.76

0.57

1.00

0.97

 

0.79

0.59

1.00

1.00

0.82

0.61

1.00

 

1.00

0.82

0.62

 

 

 

 

1125

Delta T

22

21

18

15

23

21

19

15

22

21

19

15

22

22

 

19

15

21

21

19

15

19

 

20

17

14

 

 

 

 

KW

2.03

2.07

2.13

2.20

2.18

2.22

2.29

2.36

2.31

2.36

2.43

2.51

2.42

2.48

 

2.55

2.64

2.52

2.58

2.66

2.74

2.61

 

2.66

2.75

2.84

 

 

 

 

 

AMPS

7.2

7.4

7.6

7.9

7.8

8.0

8.2

8.6

8.5

8.7

9.0

9.3

9.1

9.3

 

9.6

10.0

9.6

9.9

10.2

10.6

10.2

 

10.5

10.8

11.2

 

 

 

 

 

HI PR

242

261

275

287

272

293

309

322

309

333

351

367

352

379

 

400

417

396

426

450

470

438

 

471

498

519

 

 

 

 

 

LO PR

109

116

126

134

115

122

133

142

119

127

138

147

125

133

 

145

155

131

140

152

162

136

 

144

158

168

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

26.3

26.8

28.0

29.9

25.7

26.1

27.4

29.2

25.0

25.5

26.7

28.5

24.4

24.9

 

26.1

27.8

23.2

23.7

24.8

26.4

21.5

 

21.9

23.0

24.5

 

 

 

 

 

S/T

0.91

0.87

0.79

0.64

0.94

0.91

0.82

0.66

0.96

0.93

0.84

0.68

0.99

0.96

 

0.86

0.70

1.00

0.99

0.90

0.73

1.00

 

1.00

0.91

0.73

 

 

 

 

875

Delta T

25

25

23

20

25

25

24

20

25

25

24

20

25

25

 

24

21

24

25

23

20

23

 

23

22

19

 

 

 

 

KW

1.98

2.02

2.08

2.15

2.13

2.17

2.24

2.31

2.25

2.30

2.37

2.45

2.37

2.42

 

2.49

2.57

2.46

2.51

2.59

2.68

2.54

 

2.60

2.68

2.77

 

 

 

 

 

AMPS

7.0

7.2

7.4

7.7

7.6

7.8

8.0

8.3

8.2

8.4

8.7

9.0

8.8

9.0

 

9.3

9.7

9.4

9.6

9.9

10.3

9.9

 

10.2

10.5

10.9

 

 

 

 

 

HI PR

235

253

267

279

264

284

300

313

300

323

341

356

342

368

 

388

405

384

414

437

456

425

 

457

483

503

 

 

 

 

 

LO PR

105

112

122

130

111

118

129

138

116

123

134

143

121

129

 

141

150

127

135

148

157

132

 

140

153

163

 

 

 

 

 

MBh

28.5

29.0

30.4

32.4

27.8

28.3

29.7

31.7

27.1

27.7

29.0

30.9

26.5

27.0

 

28.3

30.1

25.1

25.6

26.8

28.6

23.3

 

23.7

24.9

26.5

 

 

 

 

 

S/T

0.94

0.91

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.96

0.87

0.71

1.00

0.99

 

0.90

0.73

1.00

1.00

0.93

0.76

1.00

 

1.00

0.94

0.76

 

 

85

 

1000

Delta T

25

24

23

20

25

24

23

20

25

24

23

20

24

25

 

23

20

23

24

23

20

21

 

22

21

19

 

 

 

KW

2.03

2.07

2.13

2.20

2.18

2.22

2.29

2.36

2.31

2.36

2.43

2.51

2.42

2.48

 

2.55

2.64

2.52

2.58

2.66

2.74

2.61

 

2.66

2.75

2.84

 

 

 

 

 

AMPS

7.2

7.4

7.6

7.9

7.8

8.0

8.2

8.6

8.5

8.7

9.0

9.3

9.1

9.3

 

9.6

10.0

9.6

9.9

10.2

10.6

10.2

 

10.5

10.8

11.2

 

 

 

 

 

HI PR

242

261

275

287

272

293

309

322

309

333

351

367

352

379

 

400

417

396

426

450

470

438

 

471

498

519

 

 

 

 

 

LO PR

109

116

126

134

115

122

133

142

119

127

138

147

125

133

 

145

155

131

140

152

162

136

 

144

158

168

 

 

 

 

 

MBh

29.3

29.9

31.3

33.4

28.6

29.2

30.6

32.6

27.9

28.5

29.8

31.8

27.3

27.8

 

29.1

31.1

25.9

26.4

27.7

29.5

24.0

 

24.5

25.6

27.3

 

 

 

 

 

S/T

0.98

0.95

0.86

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

 

0.94

0.76

1.00

1.00

0.98

0.79

1.00

 

1.00

0.98

0.80

 

 

 

 

1125

Delta T

24

23

22

19

23

23

22

19

23

23

22

19

22

23

 

22

19

21

22

22

19

20

 

20

21

18

 

 

 

 

KW

2.04

2.08

2.15

2.21

2.19

2.24

2.31

2.38

2.33

2.37

2.45

2.53

2.44

2.49

 

2.57

2.66

2.54

2.60

2.68

2.77

2.63

 

2.69

2.77

2.86

 

 

 

 

 

AMPS

7.3

7.4

7.7

8.0

7.9

8.1

8.3

8.6

8.5

8.8

9.0

9.4

9.1

9.4

 

9.7

10.0

9.7

10.0

10.3

10.7

10.3

 

10.6

10.9

11.3

 

 

 

 

 

HI PR

245

263

278

290

275

296

312

326

312

336

355

370

356

383

 

404

422

400

431

455

474

442

 

476

503

524

 

 

 

 

 

LO PR

110

117

127

136

116

123

135

143

120

128

140

149

126

135

 

147

156

133

141

154

164

137

 

146

159

170

 

33

 

* Entering Indoor Dry Bulb Temperature

 

 

NOTE: Shaded area is AHRI Rating Conditions

 

 

 

 

 

AMPS=outdoor unit amps (comp.+fan)

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction service valves.

 

 

 

 

 

 

 

 

 

 

KW=Total system power

 

 

 

 

 

 

COOLING PERFORMANCE DATA GSX130301B*/VSX130301A*

Page 33
Image 33
Goodman Mfg GSX 10.4 10.8, 381 410 432 451, 478 498, 136 114 122, 126 134 146 156, 151 161, 31.9 26.7 27.2, 25.0 26.7, 370