COOLING PERFORMANCE DAT A GSX130603A*

MODEL: GSX130603 A* / CA*F4961*6A* EXPANDED PERFORMANCE DAT A COOLIN G OPER ATION

Outdoor Ambient Tempe r ature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 5963677159636771596367715963677159636771596367 71
MBh 50.1 51.9 56.8 - 48.9 50.7 55.5 - 47.7 49.5 54.2 - 46.6 48.3 52.9 - 44.2 45.8 50.2 - 41.0 42.5 46.5 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.64 0.44 - 0.77 0.64 0.44 -
Delta T 21 18 13 - 21 18 14 - 21 18 14 - 21 18 14 - 21 18 14 - 19 17 13 -
1500 KW 4.03 4.10 4.22 - 4.30 4.38 4.50 - 4.54 4.62 4.76 - 4.75 4.84 4.98 - 4.93 5.02 5.17 - 5.08 5.18 5.34 -
AMPS 9.1 9.3 9.6 - 9.8 10.0 10.3 - 10.6 10.8 11.2 - 11.3 11.6 11.9 - 12.0 12.3 12.7 - 12.7 13.0 13.4 -
HI PR 230 247 261 - 258 277 293 - 293 315 333 - 334 359 379 - 375 404 427 - 415 446 471 -
LO PR 103 109 120 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 16 12 -
70 1750 KW 4.12 4.19 4.31 - 4.39 4.48 4.61 - 4.64 4.73 4.87 - 4.86 4.95 5.10 - 5.04 5.14 5.29 - 5.20 5.30 5.46 -
AMPS 9.3 9.5 9.8 - 10.0 10.3 10.6 - 10.9 11.1 11.5 - 11.6 11.9 12.3 - 12.3 12.6 13.0 - 13.0 13.4 13.8 -
HI PR 237 255 269 - 266 286 302 - 302 325 343 - 344 370 391 - 387 417 440 - 428 460 486 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 55.9 57.9 63.4 - 54.6 56.5 62.0 - 53.3 55.2 60.5 - 52.0 53.9 59.0 - 49.4 51.2 56.1 - 45.7 47.4 51.9 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 13 - 19 16 12 - 18 15 12 -
2000 KW 4.14 4.22 4.34 - 4.43 4.51 4.64 - 4.67 4.76 4.90 - 4.89 4.99 5.14 - 5.08 5.18 5.33 - 5.24 5.34 5.51 -
AMPS 9.4 9.6 9.9 - 10.1 10.4 10.7 - 11.0 11.2 11.6 - 11.7 12.0 12.4 - 12.4 12.7 13.2 - 13.2 13.5 13.9 -
HI PR 239 257 272 - 268 289 305 - 305 328 347 - 348 374 395 - 391 421 444 - 432 465 491 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 50.9 52.4 56.7 60.9 49.7 51.2 55.4 59.5 48.5 50.0 54.1 58.1 47.3 48.8 52.8 56.6 45.0 46.3 50.1 53.8 41.7 42.9 46.4 49.8
S/T 0.760.680.510.330.790.700.530.340.810.720.550.350.830.75 0.56 0.36 0.87 0.77 0.59 0.38 0.87 0.78 0.59 0.38
Delta T2422181224221813242218132422 18 13 24 22 18 12 22 21 17 12
1500 KW 4.06 4.13 4.25 4.37 4.33 4.41 4.54 4.67 4.57 4.66 4.79 4.94 4.78 4.88 5.02 5.17 4.96 5.06 5.21 5.37 5.12 5.22 5.38 5.54
AMPS 9.2 9.4 9.7 10.0 9.9 10.1 10.4 10.8 10.7 10.9 11.3 11.7 11.4 11.7 12.0 12.5 12.1 12.4 12.8 13.3 12.8 13.1 13.5 14.0
HI PR 232 250 264 275 260 280 296 309 296 319 336 351 337 363 383 400 379 408 431 450 419 451 476 497
LO PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161
MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3 52.8 57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0
S/T 0.790.710.530.340.820.730.550.360.840.750.570.360.860.77 0.59 0.38 0.90 0.80 0.61 0.39 0.91 0.81 0.61 0.39
Delta T2321171223211712232117122321 18 12 23 21 17 12 21 20 16 11
75 1750 KW 4.15 4.22 4.34 4.46 4.43 4.51 4.64 4.77 4.67 4.76 4.90 5.05 4.89 4.99 5.14 5.29 5.08 5.18 5.33 5.50 5.24 5.34 5.51 5.68
AMPS 9.4 9.6 9.9 10.3 10.1 10.4 10.7 11.1 11.0 11.2 11.6 12.0 11.7 12.0 12.4 12.8 12.4 12.7 13.2 13.6 13.2 13.5 13.9 14.4
HI PR 239 257 272 283 268 289 305 318 305 328 347 362 348 374 395 412 391 421 444 463 432 465 491 512
LO PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166
MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8 54.4 58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6
S/T 0.830.740.560.360.860.770.580.370.880.790.590.380.910.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T2220161122201611222016112220 17 11 22 20 16 11 20 19 15 11
2000 KW 4.17 4.25 4.37 4.50 4.46 4.54 4.67 4.81 4.71 4.80 4.94 5.09 4.93 5.03 5.18 5.33 5.12 5.22 5.38 5.54 5.28 5.39 5.55 5.72
AMPS 9.5 9.7 10.0 10.4 10.2 10.5 10.8 11.2 11.1 11.3 11.7 12.1 11.8 12.1 12.5 12.9 12.6 12.9 13.3 13.8 13.3 13.6 14.0 14.6
HI PR 242 260 274 286 271 292 308 321 308 332 350 365 351 378 399 416 395 425 449 468 436 470 496 517
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=out door unit am ps (c om p. + fan)
High and low pressures are measured at the liquid and suction service v alves. KW=Total system power