42
COOLING PERFORMANCE DAT A GSX130363A*

MODEL: GSX130363 A* / CA*F3636*6C* EXPANDED PERFORMANCE DATA COOLING OPERATION

Outdoor Ambient Tem perature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159636771596367715963677159636771
MBh 31.1 32.2 35.3 - 30.4 31.5 34.5 - 29.6 30.7 33.7 - 28.9 30.0 32.8 - 27.5 28.5 31.2 - 25.4 26.4 28.9 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 13 - 18 15 12 -
1050 KW 2.42 2.47 2.54 - 2.60 2.65 2.73 - 2.75 2.81 2.89 - 2.88 2.94 3.04 - 3.00 3.06 3.16 - 3.10 3.16 3.26 -
AMPS 6.1 6.3 6.5 - 6.6 6.7 7.0 - 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.1 8.3 8.5 - 8.5 8.7 9.0 -
HI PR 224 242 255 - 252 271 286 - 286 308 326 - 326 351 371 - 367 395 417 - 406 436 461 -
LO PR 103 109 120 - 109 1 16 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
MBh 33.7 34.9 38.2 - 32.9 34.1 37.4 - 32.1 33.3 36.5 - 31.3 32.5 35.6 - 29.8 30.8 33.8 - 27.6 28.6 31.3 -
S/T 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 1200 KW 2.48 2.53 2.60 - 2.66 2.71 2.79 - 2.81 2.87 2.96 - 2.95 3.02 3.11 - 3.07 3.14 3.24 - 3.17 3.24 3.34 -
AMPS 6.3 6.4 6.6 - 6.8 6.9 7.1 - 7.3 7.5 7.7 - 7.8 8.0 8.3 - 8.3 8.5 8.8 - 8.8 9.0 9.3 -
HI PR 231 249 263 - 260 279 295 - 295 318 336 - 336 362 382 - 378 407 430 - 418 450 475 -
LO PR 106 113 123 - 112 1 19 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 34.7 36.0 39.4 - 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.4 36.6 - 30.7 31.8 34.8 - 28.4 29.4 32.2 -
S/T 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1350 KW 2.50 2.55 2.62 - 2.68 2.73 2.81 - 2.84 2.90 2.98 - 2.98 3.04 3.13 - 3.10 3.16 3.26 - 3.20 3.27 3.37 -
AMPS 6.3 6.5 6.7 - 6.8 7.0 7.2 - 7.4 7.6 7.8 - 7.9 8.1 8.3 - 8.4 8.6 8.9 - 8.9 9.1 9.4 -
HI PR 234 252 266 - 262 282 298 - 298 321 339 - 340 366 386 - 382 411 434 - 422 454 480 -
LO PR 107 114 124 - 113 1 20 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 31.632.535.237.830.931.834.436.930.131.033.636.129.430.3 32.8 35.2 27.9 28.8 31.1 33.4 25.9 26.6 28.8 31.0
S/T 0.790.710.540.340.820.730.550.360.840.750.570.370.870.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.61 0.40
Delta T2220171122201712222017122221 17 12 22 20 17 11 21 19 16 11
1050 KW 2.44 2.49 2.56 2.64 2.62 2.67 2.75 2.83 2.77 2.83 2.91 3.01 2.91 2.97 3.06 3.16 3.02 3.09 3.18 3.29 3.12 3.19 3.29 3.40
AMPS 6.2 6.3 6.5 6.7 6.6 6.8 7.0 7.3 7.2 7.4 7.6 7.9 7.7 7.9 8.1 8.4 8.2 8.3 8.6 8.9 8.6 8.8 9.1 9.5
HI PR 227 244 258 269 254 274 289 3 02 289 311 329 343 330 355 375 391 371 399 421 43 9 410 441 466 486
LO PR 104 111 121 129 110 117 128 136 114 121 133 141 120 128 139 148 126 134 146 155 130 138 151 161
MBh 34.235.338.241.033.534.437.340.032.733.636.439.131.932.8 35.5 38.1 30.3 31.2 33.7 36.2 28.0 28.9 31.2 33.5
S/T 0.820.730.560.360.850.760.580.370.870.780.590.380.900.80 0.61 0.39 0.93 0.83 0.63 0.41 0.94 0.84 0.64 0.41
Delta T2220161122201611222016112220 17 11 22 20 16 11 20 19 15 11
75 1200 KW 2.50 2.55 2.62 2.70 2.68 2.73 2.82 2.90 2.84 2 .90 2.98 3.08 2.98 3.04 3.13 3.23 3.10 3.16 3.26 3.37 3.20 3.27 3.37 3.48
AMPS 6.3 6.5 6.7 6.9 6.8 7.0 7.2 7.5 7.4 7.6 7.8 8.1 7.9 8.1 8.3 8.6 8.4 8.6 8.9 9.2 8.9 9.1 9.4 9.7
HI PR 234 252 266 277 262 282 298 3 11 298 321 339 354 340 366 386 403 382 411 434 45 3 422 454 480 501
LO PR 107 114 124 133 113 120 131 140 118 125 137 146 124 131 144 153 130 138 150 160 134 143 156 166
MBh 35.336.339.342.234.535.538.441.233.634.637.540.232.833.8 36.6 39.3 31.2 32.1 34.7 37.3 28.9 29.7 32.2 34.5
S/T 0.860.770.580.370.890.800.600.390.910.820.620.400.940.84 0.64 0.41 0.98 0.88 0.66 0.43 0.99 0.88 0.67 0.43
Delta T2119161121191611211916112119 16 11 21 19 16 11 19 18 15 10
1350 KW 2.52 2.57 2.64 2.72 2.70 2.75 2.84 2.92 2.86 2.92 3.01 3.10 3.00 3.06 3.16 3.26 3.12 3.19 3.29 3.39 3.23 3.29 3.40 3.51
AMPS 6.4 6.5 6.7 7.0 6.9 7.0 7.3 7.5 7.5 7.6 7.9 8.2 8.0 8.1 8.4 8.7 8.5 8.7 8.9 9.3 8.9 9.2 9.5 9.8
HI PR 236 254 268 280 265 285 301 3 14 301 324 342 357 343 369 390 407 386 415 439 45 8 427 459 485 506
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions AMPS=outdoor unit amps (com p.+ fan)
High and low pressures are measured at the liquid and suction service va lv es . KW=Total syst em power