CONDENSING UNIT SPECIFICATIONS | VSX130[18 & 60]1B* | |||
|
|
|
|
|
| VSX130181B* | VSX130601B* |
|
|
|
|
|
|
|
Cooling Capacity, BTUH | 18,000 | 60,000 |
|
|
SEER/EER | 13 / 11 | 13 / 11 |
|
|
|
|
|
|
|
Compressor |
|
|
|
|
R.L. Amps | 6.70 | 25.0 |
|
|
L.R. Amps | 40.0 | 134.0 |
|
|
High Pressure Switch |
|
|
|
|
Open | N/A | N/A |
|
|
Close | N/A | N/A |
|
|
Condenser Fan Motor |
|
|
|
|
Horsepower | 1/6 | 1/4 |
|
|
F.L. Amps | 1.10 | 1.50 |
|
|
Liquid Line, Inches O.D.* | 3/8" | 3/8" |
|
|
Suction Line, Inches O.D.* | 3/4" | 1 1/8" |
|
|
Refrigerant Charge | 71.0 | 125.0 |
|
|
Power Supply |
|
| ||
Minimum Circuit Ampacity(1) | 9.5 | 26.3 |
|
|
Maximum Overcurrent Device(2) | 15 | 45 |
|
|
Electrical Conduit Size |
|
|
|
|
Power Supply (Inches) | 1/2 or 3/4 | 1/2 or 3/4 |
|
|
Approximate Shipping Weight | 135 | 200 |
|
|
(1)Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)Maximum Overcurrent Protection Device: MUST use time delay fuses or
NOTES:
*Always check the S&R plate for electrical data on the unit being installed.
*Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
*Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
*Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
11