CONDENSING UNIT SPECIFICATIONS
8
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
GSX130181C*
GSX130181C*
Cooling Capacity, BTUH 18,000
SEER/EER 13 / 11
Compressor
R.L. Amps 6.70
L.R. Amps 40.0
High Pressure Switch
Open N/ A
Close N/A
Condenser Fan M ot or
Horsepower 1/6
F.L. Amps 1.10
Liquid Line, Inc hes O .D .* 3/8"
Suction Line, In ches O .D .* 3/4"
Refrigerant Charge 71.0
Power Supply 2 08/230-60-1
Minimum Cir cuit Ampaci ty(1) 9.5
Maximum Overcurrent Device(2) 15
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4
Appro xim at e Shi p ping We igh t 135
(1) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2) Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.