CONDENSING UNIT SPECIFICATIONS
10
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire only.
VSX130[18-60]1A*
(1) Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2) Maximum Overcurrent Protection Device: MUST use time delay fuses or HACR-type Circuit Breakers of the same size as noted.
NOTES:
* Always check the S&R plate for electrical data on the unit being installed.
* Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
* Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
* Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED
BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
VSX130181A* VSX130241A* VSX130301A*
Cooling Capacity, BTUH 18,000 24,000 30,000
SEER/E ER 13 / 11 13 / 11 13 / 11
Compressor
R.L. Amps 9.00 13.5 12.8
L.R. Amps 48.0 58.3 64.0
High Pressure Switch
Open N/A N/A N/A
Close N/A N/A N/A
Condenser Fan Motor
Horsepower 1/6 1/6 1/6
F.L. Amps 1.10 1.10 1.10
Liquid Line, In c hes O .D.* 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 3/4" 3/4" 3/4"
Refrigerant Charge 72.0 79.0 81.0
Power Supply 208/230-60-1 208/230-60-1 208 /230-60-1
Minimum Circuit Ampacity(1) 12.3 18.0 17.1
Maximum Overcurrent Device(2) 20 30 30
Electrical Conduit Size
Power Su p p l y (Inche s ) 1 /2 or 3/4 1/2 or 3/ 4 1/2 or 3/ 4
Approx im ate Shi p pi ng Weigh t 149 151 152
VSX130361A* VSX130421A* VSX130481A*
Cooling Capacity, BTUH 36,000 42,000 48,000
SEER/E ER 13 / 11 13 / 11 13 / 11
Compressor
R.L. Amps 16.7 17.
9
19.9
L.R. Amps 79.0 112.0 109.0
High Pressure Switch
Open N/A N/A N/A
Close N/A N/A N/A
Condenser Fan Motor
Horsepower 1/6 1/4 1/4
F.L. Amps 1.10 1.50 1.50
Liquid Line, In c hes O .D.* 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 3/4" 7/8" 7/8"
Refrigerant Charge 95.0 124.0 128.0
Power Supply 208/230-60-1 208/230-60-1 208 /230-60-1
Minimum Circuit Ampacity(1) 21.9 23.9 26.3
Maximum Overcurrent Device(2) 35 40 45
Electrical Conduit Size
Power Su p p l y (Inche s ) 1 /2 or 3/4 1/2 or 3/ 4 1/2 or 3/ 4
Approx im ate Shi p pi ng Weigh t 197 194 195