Fujitsu P/N9359944058 manual Cleaning and Care, Pull the air filters upward to remove them

Page 13

CLEANING AND CARE

Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord. CAUTION! ● Be sure the intake grille is installed securely.

When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.

Cleaning the Air Filter

1.Pull out both sides and the center of the intake grille.

About 30 mm

 

(1-3/16”)

Side Panel

 

 

Hook

 

Notch

Arm

Arm

 

 

Intake Grille

2. Pull the air filters upward to remove them.

Push the air filter handles away from the intake grille in direction 1, then pull out the air filters.

1

Air Filter

Bracket

Base

Handle

Intake Grille

3. Clean the air filters.

Remove the dust from the air filters by vacuuming or washing them. After washing, allow the air filters to dry thoroughly in an area protected from sunlight.

4. Re-attach the air filters to the intake grille.

1The air filters fit onto the inside of the intake grille. (figure 1)

2The bottom edges of the air filters should fit into the

filter brackets. (figure 1)

3The air filters should be pushed down so that their top edges fit under the projections at the top of the intake grille. (figure 2)

Air Filter

(Figure 1)

(Figure 2)

Filter bracket

5.Push in both sides and the center of the intake grille.

Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of mild de- tergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before rein- stalling.

If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increas- ing noise.

During periods of normal use, the air filters should be cleaned every two weeks.

When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner.

Do not expose the unit body to liquid insecticides or hairsprays.

If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry thoroughly, in advance, by operating the unit in fan mode for half a day.

En-12

Image 13
Contents Floor CONSOLE/ Under Ceiling Dual Type Safety Precautions ContentsAutomatic Operation Features and FunctionsEn-3 Name of PartsVertical Swing button Vertical SET buttonHorizontal SET button Preparation Operation To Select Mode Operation Press the START/STOP buttonTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonHeat & Cool Model Reverse cycle About Mode OperationHeating DryTimer operation Timer OperationTo Use the Program timer Press the START/STOP button Set the desired times for OFF timer and on timerTo Change the Timer Settings Sleep Timer OperationAbout the Sleep timer Manual Auto OperationTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationAbout Swing Operation Swing OperationAir flow direction set Range of swing Clean the air filters Cleaning and CarePull the air filters upward to remove them Re-attach the air filters to the intake grilleSelecting the Remote Control Unit Signal Code Symptom Problem TroubleshootingOperating Tips When Indoor and Outdoor Temperature are HighOperation and Performance Heating PerformanceAuto Restart Event of Power InterruptionMulti-type Air conditioner Simultaneous Use of Multiple UnitsEn-17