Fujitsu P/N9359944058 manual To Select Mode Operation Press the START/STOP button

Page 7

OPERATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

To Select Mode Operation

1

2

Press the START/STOP button.

The indoor unit’s OPERATION indicator lamp (red) will light. The air conditioner will start operating.

Press the MASTER CONTROL button to select the de- sired mode.

Each time the button is pressed, the mode will change in the following order:

 

sAUTO

sCOOL

 

 

s DRY

 

 

 

 

 

 

 

 

*HEATt

FANt

 

 

 

About three seconds later, the entire display will reappear.

Example: When set to COOL

To Set the Thermostat

Press the SET TEMP. buttons.

button: Press to rise the thermostat setting. button: Press to lower the thermostat setting.

Thermostat setting range:

AUTO

64 to 88 °F

* Heating

60 to 88 °F

Cooling/Dry

64 to 88 °F

The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the remote control unit’s display).

About three seconds later, the entire display will reappear.

 

 

 

 

 

 

 

 

 

 

 

 

The thermostat setting should be considered a standard value, and may differ

 

 

 

Example: When set to 88 °F

somewhat from the actual room temperature.

 

 

 

 

To Set the Fan Speed

Press the FAN CONTROL button.

Each time the button is pressed, the fan speed changes in the following order:

sAUTO sHIGH sMED sLOW

About three seconds later, the entire display will reappear.

When set to AUTO:

*Heating : Fan operates so as to optimally circulate warmed air.

 

However, the fan will operate at very low speed when the temperature

 

 

 

 

 

 

of the air issued from the indoor unit is low.

 

 

 

 

 

Cooling

: As the room temperature approaches that of the thermostat setting,

 

 

 

 

 

 

 

 

 

 

 

the fan speed becomes slower.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

: The fan alternately turns on and off; when on, the fan runs at the low

Example: When set to AUTO

 

fan speed.

 

 

 

 

 

 

The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.

To Stop Operation

Press the START/STOP button.

The OPERATION indicator lamp (red) will go out.

En-6

Image 7
Contents Floor CONSOLE/ Under Ceiling Dual Type Safety Precautions ContentsAutomatic Operation Features and FunctionsEn-3 Name of PartsVertical Swing button Vertical SET buttonHorizontal SET button Preparation To Set the Fan Speed Press the FAN Control button To Select Mode Operation Press the START/STOP buttonOperation To Set the Thermostat Press the SET TEMP. buttonsDry About Mode OperationHeat & Cool Model Reverse cycle HeatingSet the desired times for OFF timer and on timer Timer OperationTimer operation To Use the Program timer Press the START/STOP buttonManual Auto Operation Sleep Timer OperationTo Change the Timer Settings About the Sleep timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationAbout Swing Operation Swing OperationAir flow direction set Range of swing Re-attach the air filters to the intake grille Cleaning and CareClean the air filters Pull the air filters upward to remove themSelecting the Remote Control Unit Signal Code Symptom Problem TroubleshootingHeating Performance When Indoor and Outdoor Temperature are HighOperating Tips Operation and PerformanceSimultaneous Use of Multiple Units Event of Power InterruptionAuto Restart Multi-type Air conditionerEn-17