Fujitsu P/N9359944058 manual Vertical SET button, Vertical Swing button, Horizontal SET button

Page 5

Fig. 1 Indoor Unit

1Operating Control Panel (Fig. 2)

2 MANUAL AUTO button

3 Remote Control Signal Receiver

4 OPERATION Indicator Lamp (red)

5 TIMER Indicator Lamp (green)

6 SWING Indicator Lamp (orange)

(VERTICAL SWING)

7 SWING Indicator Lamp (orange)

(HORIZONTAL SWING)

If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See page 16 Auto Restart).

8Intake Grille (Fig. 3)

9 Air Filter

0 UP/DOWN Air Direction Flaps

A RIGHT/LEFT Air Direction Louvers (behind UP/DOWN Air Direction Flaps)

B Drain Hose

Fig. 4 Remote Control Unit

CSLEEP button

DMASTER CONTROL button

ESET TEMP./SET TIME buttons () F Signal Transmitter

G TIMER button

H FAN CONTROL button I START/STOP button

J AIR FLOW DIRECTION

VERTICAL SET button

K AIR FLOW DIRECTION

VERTICAL SWING button

L AIR FLOW DIRECTION

HORIZONTAL SET button

M AIR FLOW DIRECTION

HORIZONTAL SWING button N TIME ADJUST button

O ACL button

Rear side (Fig. 5)

PTEST RUN

Touch the two metal contacts with a me- tallic object to send the signal to perform a test run.

Perform a test run only when installing the air conditioner. If the signal to perform a test run is received during normal opera- tion, the air conditioner’s thermostat will malfunction.

If the signal to perform a test run is re- ceived during normal operation, the unit will switch to the test operation mode and the indoor unit’s OPERATION and TIMER indicator lamps will flash simultaneously.

To stop the test operation mode, press the START/STOP button to stop the air condi- tioner.

QRemote Control Unit Display (Fig. 6) R Transmit Indicator

S Clock Display

T Operating Mode Display U T imer Mode Display V Fan Speed Display

W Temperature Set Display X T imer Set Indicator

Y Temperature Set Indicator

En-4

Image 5
Contents Floor CONSOLE/ Under Ceiling Dual Type Safety Precautions ContentsAutomatic Operation Features and FunctionsEn-3 Name of PartsHorizontal SET button Vertical SET buttonVertical Swing button Preparation Operation To Select Mode Operation Press the START/STOP buttonTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonHeat & Cool Model Reverse cycle About Mode OperationHeating DryTimer operation Timer OperationTo Use the Program timer Press the START/STOP button Set the desired times for OFF timer and on timerTo Change the Timer Settings Sleep Timer OperationAbout the Sleep timer Manual Auto OperationTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationAir flow direction set Range of swing Swing OperationAbout Swing Operation Clean the air filters Cleaning and CarePull the air filters upward to remove them Re-attach the air filters to the intake grilleSelecting the Remote Control Unit Signal Code Symptom Problem TroubleshootingOperating Tips When Indoor and Outdoor Temperature are HighOperation and Performance Heating PerformanceAuto Restart Event of Power InterruptionMulti-type Air conditioner Simultaneous Use of Multiple UnitsEn-17