SWING OPERATION

Begin air conditioner operation before performing this procedure

To select Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button .

The SWING indicator light (VERTICAL SWING) (orange) will turn on.

In this mode, the UP/DOWN air direction flap will swing automatically to direct the air flow both up and down.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Vertical airflow SWING Operation

Example: When set to vertical swing

Press the AIR FLOW DIRECTION VERTICAL SWING button once again.

The SWING indicator light (VERTICAL SWING) will turn off. Airflow direction will return to the setting before swing was begun.

About Vertical Airflow Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

 

 

1

1 to 3

2

1 to 3

 

 

3

2 to 4

 

 

4

3 to 5

5

1 to 5 (All range)

 

 

Air direction range (See page 11, Fig. 8)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION VERTICAL SET button to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flap, in the Heating range (4 to 5) for long periods of time, since water vapor may con- dense near the outlet port and drops of water may drip from the air conditioner.

To select Horizontal Airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button.

The SWING indicator light (HORIZONTAL SWING) (orange) will turn on.

In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct the airflow both right and left.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Horizontal airflow SWING Operation

Example: When set to horizontal swing

Press the AIR FLOW DIRECTION HORIZONTAL SWING button once again.

The SWING indicator light (HORIZONTAL SWING) will turn off.

Airflow direction will return to the setting before swing was begun.

About Horizontal Airflow Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 5 (All range)

2

1 to 3

 

 

3

2 to 4

 

 

4

3 to 5

 

 

5

1 to 5 (All range)

 

 

Air direction range (See page 11, Fig.9)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but- ton to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

En-12

Image 12
Contents Page Contents Safety PrecautionsFeatures and Functions Automatic OperationName of Parts Electrical BreakerTime Adjust Button O Test RUN Button Outdoor Unit Intake side B Outlet sidePreparation To Select Mode Operation Press the START/STOP button OperationTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonAbout Mode Operation Timer Operation Sleep Timer Operation About the Program timerAbout the on timer About the Sleep timerAdjusting the Direction of AIR Circulation Types of Air flow Direction SettingSwing Operation To Stop Vertical airflow Swing OperationTo Stop Horizontal airflow Swing Operation About Vertical Airflow Swing OperationEnergy Save Operation Manual Auto OperationAbout the Energy Save Cleaning and Care Clean the air filtersRe-attach the air filters to the intake grille Troubleshooting Symptom ProblemWhen Indoor and Outdoor Temperature are High Operating TipsOperation and Performance Low Ambient CoolingTemperature and Humidity Range Event of Power InterruptionAuto Restart