FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neigh- bor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance (if appli- cable).

4.Lower valve cover.

5.Push in gas control knob slightly and turn clockwise to "OFF".

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Find pilot - The pilot is attached to the main burner behind the front log.

8.Turn knob on gas control counterclockwise to "PILOT."

9.Push in gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Attention! Gas control has an INTERLOCK latching device. When the pilot is initially lit and the safety magnet is energized (pilot stays "ON") the INTER- LOCK latching device becomes operative. If the gas control is turned to the "OFF" position or gas flow to the appliance is shut off, the pilot cannot be relighted until the safety magnet is de-energized (approxi- mately 60 seconds). There will be an audible "click" when the safety magnet in the gas control is de- energized. Pilot can now be relighted. Repeat steps 5 through 9.

11.Turn gas control knob counterclockwise to "ON".

12.Raise valve cover.

13.Turn on all electric power to the appliance (if appli- cable).

14.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to appliance if service is to be performed (if applicable).

3.Lower valve cover.

4.Push in gas control knob slightly and turn clock-

wise to "OFF". Do not force.

5.Raise valve cover.

Page 14

R-3451

Image 14
Contents Installation Instructions This heater is equipped with a Pilot Light Safety SYS Instructions to InstallerServiced If heater keeps shutting off, have it serviced. Keep burnerSafety Information for Users of LP-GAS Qualified Installing Agency SpecificationsAccessories Installation on Rugs and Vinyl3451 Page Page Stone Inlay Replacement of Standard Grille Top Installation of Optional Stone InlayInstalling a New Main Gas Cock Parts ListInstallation of Wire Channel Assembly Figure Method of Installing a Tee Fitting Sediment TrapCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Checking Manifold PressureHigh Altitudes Operation of ON/OFF/REMOTE Switch with no Accessories Cleaning the Log Set and FireboxCIVF-25 ON/OFF/REMOTE Switch Wall Switch, FWS-1Manual Operation Installation of Remote Receiver FigureWiring Diagram Figure Wall Thermostat OperationCleaning Procedure Figure Maintenance & Service InstructionsClean Burner and Control Compartment Operating GuidelinesFor Your Safety Read Before Lighting Gas odor even when control knob is in OFF position Delayed ignition of main burnerHeater produces a whistling noise when main burner is lit Main burner does not light after ODS/pilot is litHow To Order Repair Parts Parts List for CIVF-25 Firebox 3451 Fan Control Installing Optional CIB-2 BlowerWiring Cleaning Blower Motor

CIVF-25-2 specifications

Empire Comfort Systems CIVF-25-2 is a distinguished wall-mounted vent-free gas fireplace that brings warmth and ambiance to any space. This elegant unit is designed to efficiently deliver heat while offering a stylish aesthetic that enhances home décor. The CIVF-25-2 stands out due to its unique combination of features, technologies, and characteristics.

One of the main features of the Empire Comfort Systems CIVF-25-2 is its adjustable air shutter system. This allows users to control the flame height and intensity, providing the flexibility to create the perfect atmosphere for any occasion. The fireplace is equipped with a state-of-the-art burner system that ensures a clean and efficient burn, maximizing heat output while minimizing emissions.

The CIVF-25-2 operates using either natural gas or propane. This versatility allows homeowners to choose the fuel source that best fits their needs. The unit also features a safety pilot system that includes an automatic shut-off function, ensuring peace of mind for users. This pilot system is designed to operate even during power outages, making it a reliable source of heat during adverse weather conditions.

In terms of aesthetics, the CIVF-25-2 is available in various styles and finishes, allowing it to complement any interior design. The elegant front glass creates a stunning visual impact while also providing a safe barrier from the flames, making it ideal for households with children or pets. Additionally, the fireplace’s minimalist design ensures it can fit seamlessly into smaller spaces without sacrificing heat output.

Another noteworthy characteristic is the easy installation process. The vent-free design means that it does not require a traditional chimney or venting system, which simplifies the setup and reduces installation costs. This feature allows homeowners to enjoy the benefits of a fireplace without the complexities typically associated with traditional fireplaces.

In summary, the Empire Comfort Systems CIVF-25-2 offers a blend of modern technology, safety features, and stylish design. With its adjustable air shutter, versatile fuel options, safety pilot system, and easy installation, it is an excellent choice for anyone looking to enhance their home with the warmth and charm of a gas fireplace.