Empire Comfort Systems CIVF-25-2 installation instructions

Page 7

Figure 5

Figure 6

10.Attach the (4) 1-1/4" x 1/2" retaining tabs to the casing front with (4) 3/8" bolts. The retaining tabs should be positioned downward, from the casing front, top to the casing front, bottom.

11.Refer to Figure 8, attach casing front to outer casing by using the

(4) retaining tabs on the casing front. The (2) top, retaining tabs on the casing front will be placed behind the (2) top, locator tabs on the front of the casing sides. The (2) bottom, retaining tabs will be inserted into the (2) 9/16" slots on the front, leg pads. Place the top, retaining tabs behind the top, locator tabs as you pivot inward the bottom of the casing front in order to insert the bottom, retaining tabs into the slots.

12.The following procedure will provide a snug fit between the casing front and the casing sides. Grasp the right, front leg, push inward on the leg in order to provide a snug fit between the casing front and the casing side. Continue to hold the right, front leg as you completely tighten the (2) 3/8" bolts that attach the leg pad to the right, casing side. Repeat procedure for left, front leg to achieve a snug fit between the casing front and the casing side.

13.Remove the casing front from the outer casing.

14.Refer to Figure 9, the appliance firebox can now be inserted into the outer casing. Center the firebox in the outer casing. Attention: Remove (1) Phillips-head screw in the top of the valve cover. The screw is used to secure the valve cover in place during shipping. The (1) Phillips-head screw can be discarded.

15.Attach casing front to outer casing as described in Step 11.

16.Place the casing top onto the outer casing. The casing top nests into the outer casing.

17.Insert center grille, left grille and right grille into casing top.

18.Level appliance by adjusting leveling bolts.

19.Assembly of cast iron (outer casing) stove casting is completed.

R-3451

Page 7

Image 7
Contents Installation Instructions If heater keeps shutting off, have it serviced. Keep burner Instructions to InstallerServiced This heater is equipped with a Pilot Light Safety SYSSafety Information for Users of LP-GAS Installation on Rugs and Vinyl SpecificationsAccessories Qualified Installing Agency3451 Page Page Installation of Optional Stone Inlay Stone Inlay Replacement of Standard Grille TopMethod of Installing a Tee Fitting Sediment Trap Parts ListInstallation of Wire Channel Assembly Figure Installing a New Main Gas CockHigh Altitudes Checking Manifold PressureCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Wall Switch, FWS-1 Cleaning the Log Set and FireboxCIVF-25 ON/OFF/REMOTE Switch Operation of ON/OFF/REMOTE Switch with no AccessoriesWall Thermostat Operation Installation of Remote Receiver FigureWiring Diagram Figure Manual OperationOperating Guidelines Maintenance & Service InstructionsClean Burner and Control Compartment Cleaning Procedure FigureFor Your Safety Read Before Lighting Main burner does not light after ODS/pilot is lit Delayed ignition of main burnerHeater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionHow To Order Repair Parts Parts List for CIVF-25 Firebox 3451 Wiring Installing Optional CIB-2 BlowerFan Control Blower Motor Cleaning

CIVF-25-2 specifications

Empire Comfort Systems CIVF-25-2 is a distinguished wall-mounted vent-free gas fireplace that brings warmth and ambiance to any space. This elegant unit is designed to efficiently deliver heat while offering a stylish aesthetic that enhances home décor. The CIVF-25-2 stands out due to its unique combination of features, technologies, and characteristics.

One of the main features of the Empire Comfort Systems CIVF-25-2 is its adjustable air shutter system. This allows users to control the flame height and intensity, providing the flexibility to create the perfect atmosphere for any occasion. The fireplace is equipped with a state-of-the-art burner system that ensures a clean and efficient burn, maximizing heat output while minimizing emissions.

The CIVF-25-2 operates using either natural gas or propane. This versatility allows homeowners to choose the fuel source that best fits their needs. The unit also features a safety pilot system that includes an automatic shut-off function, ensuring peace of mind for users. This pilot system is designed to operate even during power outages, making it a reliable source of heat during adverse weather conditions.

In terms of aesthetics, the CIVF-25-2 is available in various styles and finishes, allowing it to complement any interior design. The elegant front glass creates a stunning visual impact while also providing a safe barrier from the flames, making it ideal for households with children or pets. Additionally, the fireplace’s minimalist design ensures it can fit seamlessly into smaller spaces without sacrificing heat output.

Another noteworthy characteristic is the easy installation process. The vent-free design means that it does not require a traditional chimney or venting system, which simplifies the setup and reduces installation costs. This feature allows homeowners to enjoy the benefits of a fireplace without the complexities typically associated with traditional fireplaces.

In summary, the Empire Comfort Systems CIVF-25-2 offers a blend of modern technology, safety features, and stylish design. With its adjustable air shutter, versatile fuel options, safety pilot system, and easy installation, it is an excellent choice for anyone looking to enhance their home with the warmth and charm of a gas fireplace.