Empire Comfort Systems CIVF-25-2 Main burner does not light after ODS/pilot is lit

Page 15

TROUBLE-SHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

1.When ignitor button is pressed, there is no spark at ODS/ pilot.

a.Ignitor electrode positioned wrong - Replace ignitor.

b.Ignitor electrode broken - Replace ignitor.

c.Ignitor electrode not connected to ignitor cable - Reconnect ignitor cable.

d.Ignitor cable pinched or wet - Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.

e.Broken ignitor cable - Replace ignitor cable.

f.Bad piezo ignitor - Replace piezo ignitor.

2.When ignitor button is pressed, there is spark at ODS/pilot, but no ignition.

a.Gas supply turned off or manual shutoff valve closed - Turn on gas supply or open manual shutoff valve.

b.Control knob not in PILOT position - Turn gas control knob to PILOT position.

c.Control knob not pressed in while in PILOT position - Press in control knob while in PILOT position.

d.Air in gas lines when installed - Continue holding down control knob. Repeat igniting operation until air is removed.

e.Depleted gas supply - Contact local gas company.

f.ODS/pilot is clogged - Clean ODS/pilot or replace ODS/pilot assembly.

g.Gas regulator setting is not correct - Replace gas regulator.

3.ODS/pilot lights but flame goes out when control knob is released.

a.Control knob not fully pressed in - Press in control knob fully.

b.Control knob not pressed in long enough - After ODS/pilot lights, keep control knob pressed in 30 seconds.

c.Safety interlock system has been triggered (thermostat models only) - Wait one minute for safety interlock system to reset. Repeat ignition operation.

d.Manual Shutoff valve not fully open - Fully open manual shutoff valve.

e.Thermocouple connection loose at control valve - Hand tighten until snug, then tighten 1/4 turn more.

f.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by either 1) low gas pressure - Contact local gas company or 2) dirty or partially clogged ODS/pilot - Clean ODS/pilot or replace ODS/pilot assembly.

g.Thermocouple damaged - Replace thermocouple.

h.Control valve damaged - Replace control valve.

4.Main burner does not light after ODS/pilot is lit.

a.Main burner orifice clogged - Clean main burner or replace main burner orifice.

b.Main burner orifice diameter is too small - Replace main burner orifice.

c.Inlet gas pressure is too low - Contact local gas company.

5.Pilot burning, no gas to burner, valve knob "ON", on/off switch "ON."

a."On/Off" switch, wall switch, remote control or wires defective - Check "on/off" switch and wires for proper connections. Place jumper wires across terminal at switch - if burner comes on, replace defective switch. If OK, place jumper wires across switch wires at gas valve-if burner comes on, wires are faulty or connections are bad.

b.Thermopile may not be generating sufficient millivolts - If the pilot flame is not close enough physically to the thermopile, clean the ODS/pilot.

-Be sure the wire connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket.

-Check the thermopile with a millivolt meter. Take the reading at TH-TP & TP terminals of the gas valve. The meter should read 350 millivolts minimum, while holding the valve

knob depressed in the PILOT position, with the pilot lit, and the ON/OFF switch in the OFF position. Replace the faulty thermopile if the reading is below the specified minimum.

-With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The reading should be 350 millivolts minimum. Replace the thermopile if the reading is below the minimum.

c.Defective valve - Turn valve knob to "ON." Place ON/OFF switch to "ON." Check with millivolt meter at thermopile terminals. Millivolt meter should read greater than 200 millivolts. If the reading is okay and the main burner does not ignite, replace the gas valve

d.Plugged main burner orifice - Check main burner orifice for blockage and remove.

6.Delayed ignition of main burner.

a.Manifold pressure is too low - Contact local gas company.

b.Main burner orifice clogged - Clean main burner and main burner orifice.

7.Main burner backfiring during combustion.

a.Main burner orifice is clogged or damaged - Clean main burner and main burner orifice or replace main burner orifice.

b.Damaged main burner - Replace damaged main burner.

c.Gas regulator defective - Replace gas regulator.

8.Yellow flame in front section of main burner during main burner combustion.

a.Not enough air - Check main burner for dirt and debris. If found, clean main burner.

b.Gas regulator defective - replace gas regulator.

9.Slight smoke or odor during initial operation.

a.Residues from manufacturing processes and logs curing - Problem will stop after a few hours of operation.

10.Heater produces a whistling noise when main burner is lit.

a.Turning control knob to HI position when main burner is cold

-Turn control knob to LO position and let warm up for a minute.

b.Air in gas line - Operate main burner until air is removed from line. Have gas line checked by local gas company.

c.Air passageways on heater blocked - Observe minimum installation clearances (see page 4).

d.Dirty or partially clogged main burner orifice - Clean main burner and main burner orifice or replace main burner orifice.

11.Heater produces a clicking/ticking noise just after main burner is lit or shut off.

a.Metal expanding while heating or contracting while cooling

-This is common with most heaters. If noise is excessive, contact service person.

12.Heater produces unwanted odor.

a.Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. - Open window to ventilate room. Stop using odor causing products while heater is operating.

b.Low fuel supply - Refill supply tank.

c.Gas leak - Locate and correct all leaks.

13.Heater shuts off in use (ODS operates).

a.Not enough fresh air is available - Open window and/or door for ventilation.

b.Low line pressure - Contact local gas company.

c.ODS/pilot is partially clogged - Clean ODS/pilot.

14.Gas odor even when control knob is in OFF position.

a.Gas leak - Locate and correct all leaks.

b.Control valve defective - Replace control valve.

15.Gas odor during combustion.

a.Foreign matter between logs and main burner - remove foreign matter.

b.Gas leak - Locate and correct all leaks.

R-3451

Page 15

Image 15
Contents Installation Instructions If heater keeps shutting off, have it serviced. Keep burner Instructions to InstallerServiced This heater is equipped with a Pilot Light Safety SYSSafety Information for Users of LP-GAS Installation on Rugs and Vinyl SpecificationsAccessories Qualified Installing Agency3451 Page Page Installation of Optional Stone Inlay Stone Inlay Replacement of Standard Grille TopMethod of Installing a Tee Fitting Sediment Trap Parts ListInstallation of Wire Channel Assembly Figure Installing a New Main Gas CockChecking Manifold Pressure High AltitudesCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Wall Switch, FWS-1 Cleaning the Log Set and FireboxCIVF-25 ON/OFF/REMOTE Switch Operation of ON/OFF/REMOTE Switch with no AccessoriesWall Thermostat Operation Installation of Remote Receiver FigureWiring Diagram Figure Manual OperationOperating Guidelines Maintenance & Service InstructionsClean Burner and Control Compartment Cleaning Procedure FigureFor Your Safety Read Before Lighting Main burner does not light after ODS/pilot is lit Delayed ignition of main burnerHeater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionHow To Order Repair Parts Parts List for CIVF-25 Firebox 3451 Installing Optional CIB-2 Blower WiringFan Control Blower Motor Cleaning

CIVF-25-2 specifications

Empire Comfort Systems CIVF-25-2 is a distinguished wall-mounted vent-free gas fireplace that brings warmth and ambiance to any space. This elegant unit is designed to efficiently deliver heat while offering a stylish aesthetic that enhances home décor. The CIVF-25-2 stands out due to its unique combination of features, technologies, and characteristics.

One of the main features of the Empire Comfort Systems CIVF-25-2 is its adjustable air shutter system. This allows users to control the flame height and intensity, providing the flexibility to create the perfect atmosphere for any occasion. The fireplace is equipped with a state-of-the-art burner system that ensures a clean and efficient burn, maximizing heat output while minimizing emissions.

The CIVF-25-2 operates using either natural gas or propane. This versatility allows homeowners to choose the fuel source that best fits their needs. The unit also features a safety pilot system that includes an automatic shut-off function, ensuring peace of mind for users. This pilot system is designed to operate even during power outages, making it a reliable source of heat during adverse weather conditions.

In terms of aesthetics, the CIVF-25-2 is available in various styles and finishes, allowing it to complement any interior design. The elegant front glass creates a stunning visual impact while also providing a safe barrier from the flames, making it ideal for households with children or pets. Additionally, the fireplace’s minimalist design ensures it can fit seamlessly into smaller spaces without sacrificing heat output.

Another noteworthy characteristic is the easy installation process. The vent-free design means that it does not require a traditional chimney or venting system, which simplifies the setup and reduces installation costs. This feature allows homeowners to enjoy the benefits of a fireplace without the complexities typically associated with traditional fireplaces.

In summary, the Empire Comfort Systems CIVF-25-2 offers a blend of modern technology, safety features, and stylish design. With its adjustable air shutter, versatile fuel options, safety pilot system, and easy installation, it is an excellent choice for anyone looking to enhance their home with the warmth and charm of a gas fireplace.