Empire Comfort Systems CIVF-25-2 Specifications, Stove Casting Must be ordered with Firebox

Page 4

Specifications

Model

 

CIVF-25

Input BTU/HR (KW/H) Max. (LP/NAT)

25,000 ( 7.3)

BTU/HR (KW/H) Min. LP

18,000 (5.3)

BTU/HR (KW/H) Min. Nat.

17,000 (5.0)

Height

 

27 3/4" (70.5cm)

Width

 

25 1/2" (64.8cm)

Depth

 

15 1/2" (39.4cm)

Gas Inlet

 

3/8" (9.5mm)

Stove Casting (Must be ordered with Firebox.)

 

 

 

CIFB-1

Flat Black

 

CIPB-1

Porcelain Black

 

CIPG-1

Porcelain Green

 

CIPS-1

Porcelain Sand

 

CIPN-1

Porcelain Navy

 

CIPR-1

Porcelain Red

 

Accessories

 

 

 

 

 

GWSG-T

750 Millivolt Wall Thermostat

FRBC-1

Battery Operated Remote Control

FRBTC-1

Battery Operated Remote Control

 

with Thermostat

 

FREC-1

Electric Remote Control

 

FWS-1

Wall Switch

 

CIB-2

Automatic Blower

 

Stone Inlay Replaces Standard Grille Top

CII-2

Stone Inlay

Empress Green

CII-3

Stone Inlay

Hunan Jade

CII-4

Stone Inlay

Gray Botticino

CII-5

Stone Inlay

Azul

CII-6

Stone Inlay

Salome

CII-7

Stone Inlay

Black Swan

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.*

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

Water Vapor: A By-Product of Unvented Room Heaters

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.

Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

The following steps will help insure that water vapor does not become a problem.

1.Be sure the heater is sized properly for the application, including ample combustion air and circulation air.

2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3.Do not use an unvented room heater as the primary heat source.

Page 4

Provisions for Adequate Combustion and Ventilation Air

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

The National Fuel Gas Code, ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicat- ing directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

The following example is for determining the volume of a typical area in which the CIVF-25 may be located and for determining if this area fits the definition of an unconfined space.

The maximum input of the CIVF-25 is 25,000 Btu per hour. Based on the 50 cubic feet per 1,000 Btu per hour formula, the minimum area that is an unconfined space for installation of the CIVF-25 is 1,250 cubic feet, 50 cubic feet x 25 = 1,250 cubic feet. To determine the cubic feet of the area in which the CIVF-25 is to be installed, measure the length, width and height of the area. Example: The area measures 16 feet in length, 10 feet in width and 8 feet in height, the area is 1,280 cubic feet. The CIVF- 25 can be installed in this unconfined space with no requirement to provide additional combustion and ventilation air.

Warning: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, Section 5.3 or applicable local codes.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed, and

b.Weatherstripping has been added on openable windows and doors, and

c.Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, be- tween wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If the CIVF-25 heater is installed in a building of unusually tight construction, adequate air for combustion, ventilation and dilution of flue gases shall be provided in accordance with ANSI Z223.1/NFPA54.

Clearances (Figures 1, 2 and 3)

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Top of appliance (ceiling)

24

inches

Rear Wall

2

inches

Side Wall

6

inches

Heater Corners (45° angle) to Wall

4

inches

Floor

0

inches

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

Installation on Rugs and Vinyl

If this appliance is installed directly on carpeting, vinyl or other combus- tible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

R-3451

Image 4
Contents Installation Instructions Instructions to Installer ServicedThis heater is equipped with a Pilot Light Safety SYS If heater keeps shutting off, have it serviced. Keep burnerSafety Information for Users of LP-GAS Specifications AccessoriesQualified Installing Agency Installation on Rugs and Vinyl3451 Page Page Stone Inlay Replacement of Standard Grille Top Installation of Optional Stone InlayParts List Installation of Wire Channel Assembly FigureInstalling a New Main Gas Cock Method of Installing a Tee Fitting Sediment TrapHigh Altitudes Checking Manifold PressureCorrect Pilot Flame Pattern Incorrect Pilot Flame Pattern Cleaning the Log Set and Firebox CIVF-25 ON/OFF/REMOTE SwitchOperation of ON/OFF/REMOTE Switch with no Accessories Wall Switch, FWS-1Installation of Remote Receiver Figure Wiring Diagram FigureManual Operation Wall Thermostat OperationMaintenance & Service Instructions Clean Burner and Control CompartmentCleaning Procedure Figure Operating GuidelinesFor Your Safety Read Before Lighting Delayed ignition of main burner Heater produces a whistling noise when main burner is litGas odor even when control knob is in OFF position Main burner does not light after ODS/pilot is litHow To Order Repair Parts Parts List for CIVF-25 Firebox 3451 Wiring Installing Optional CIB-2 BlowerFan Control Cleaning Blower Motor

CIVF-25-2 specifications

Empire Comfort Systems CIVF-25-2 is a distinguished wall-mounted vent-free gas fireplace that brings warmth and ambiance to any space. This elegant unit is designed to efficiently deliver heat while offering a stylish aesthetic that enhances home décor. The CIVF-25-2 stands out due to its unique combination of features, technologies, and characteristics.

One of the main features of the Empire Comfort Systems CIVF-25-2 is its adjustable air shutter system. This allows users to control the flame height and intensity, providing the flexibility to create the perfect atmosphere for any occasion. The fireplace is equipped with a state-of-the-art burner system that ensures a clean and efficient burn, maximizing heat output while minimizing emissions.

The CIVF-25-2 operates using either natural gas or propane. This versatility allows homeowners to choose the fuel source that best fits their needs. The unit also features a safety pilot system that includes an automatic shut-off function, ensuring peace of mind for users. This pilot system is designed to operate even during power outages, making it a reliable source of heat during adverse weather conditions.

In terms of aesthetics, the CIVF-25-2 is available in various styles and finishes, allowing it to complement any interior design. The elegant front glass creates a stunning visual impact while also providing a safe barrier from the flames, making it ideal for households with children or pets. Additionally, the fireplace’s minimalist design ensures it can fit seamlessly into smaller spaces without sacrificing heat output.

Another noteworthy characteristic is the easy installation process. The vent-free design means that it does not require a traditional chimney or venting system, which simplifies the setup and reduces installation costs. This feature allows homeowners to enjoy the benefits of a fireplace without the complexities typically associated with traditional fireplaces.

In summary, the Empire Comfort Systems CIVF-25-2 offers a blend of modern technology, safety features, and stylish design. With its adjustable air shutter, versatile fuel options, safety pilot system, and easy installation, it is an excellent choice for anyone looking to enhance their home with the warmth and charm of a gas fireplace.