Empire Comfort Systems BF-30-2, BF-20-2 Important Safety Information, This is a Heating Appliance

Page 3

IMPORTANT SAFETY INFORMATION

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

An unvented room heater having an input rating of

SERVICE PERSON. The appliance should be inspected

 

more than 6,000 Btu per hour shall not be installed in a

before use and at least annually by a professional service

 

bathroom.

person. More frequent cleaning may be required due to

• An unvented room heater having an input rating of more

excessive lint from carpeting, bedding materials, etc. It

is imperative that control compartments, burners and

 

than 10,000 Btu perhourshall not be installed in a bedroom

 

circulating

air passageways of the appliance be kept

 

or bathroom.

 

clean.

 

Due to high temperatures, the appliance should be located

 

• DO NOT use this room heater if any part has been under

 

out of traffic and away from furniture and draperies.

 

water. Immediately call a qualified service technician

• Children and adults should be alerted to the hazard of

to inspect the room heater and to replace any part of the

 

high surface temperature and should stay away to avoid

 

control system and any gas control which has been under

 

burns or clothing ignition.

 

water.

 

• Young children should be carefully supervised when they

 

• Keep appliance area clear and free from combustible

 

are in the same room with the appliance.

 

materials,

gasoline and other flammable vapors and

• Do not place clothing or other flammable material on or

liquids.

 

 

near the appliance.

• WARNING: ANY CHANGE TO THIS HEATER OR ITS

• Due to high surface temperatures, keep children, clothing

CONTROLS CAN BE DANGEROUS.

 

and furniture away.

Any safety screen or guard removed for servicing an

• WARNING: Do not use a blower insert, heat exchanger

appliance must be replaced prior to operating the heater.

 

insert or other accessory not approved for use with

• WARNING: Failure to keep the primary air opening(s)

 

heater.

 

of the burner(s) clean may result in sooting and property

• Installation and repair should be done by a QUALIFIED

damage.

 

 

 

 

 

WARNING

When used without adequate combustion and ventilation air,

 

CARBON MONOXIDE POISONING MAY LEAD TO

heater may give off CARBON MONOXIDE, an odorless, poi-

 

DEATH.

sonous gas.

 

Early signs of carbon monoxide poisoning resemble the flu, with

 

 

 

 

Do not install heater until all necessary provisions are made for

 

headache, dizziness and/or nausea. If you have these signs, heater

combustion and ventilation air. Consult the written instructions

 

may not be working properly. Get fresh air at once! Have heater

provided with the heater for information concerning combus-

 

serviced.

tion and ventilation air. In the absence of instructions, refer

 

Some people — pregnant women, persons with heart or lung dis-

to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air

 

ease, anemia, those under the influence of alcohol , those at high

for Combustion and Ventilation, or applicable local codes.

 

altitudes — are more affected by carbon monoxide than others.

This heater is equipped with a PILOT LIGHT SAFETY SYS-

 

The pilot light safety system senses the depletion of oxygen at

TEM designed to turn off the heater if not enough fresh air is

 

its location. If this heater is installed in a structure having a high

available.

 

vertical dimension, the possibility exists that the oxygen supply

 

 

at the higher levels will be less than that at the heater. In this type

DO NOT TAMPER WITH PILOT LIGHT SAFETY

 

of application, a fan to circulate the structure air will minimize

SYSTEM!

 

this effect. The use of this fan will also improve the comfort level

If heater shuts off, do not relight until you provide fresh air.

 

in the structure. When a fan is used to circulate air, it should be

 

located so that the air flow is not directed at the burner.

If heater keeps shutting off, have it serviced. Keep burner and

 

 

 

control compartment clean.

 

 

16943-7-0907

Page 3

Image 3
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersGAS Supply Clearances Optional Floor Stand InstallationSRS-18* and SRS-30 Floor Stand Installation Installation on Rugs and TileBF-10 and BF-20 On Sheet Rock Wall Wall Mount InstallationLighting Instructions For Your Safety Read Before LightingPiezo Pilot Ignitor Instructions Main Burner Flame CharacteristicsAir Shutter Adjustment Figure Cleaning Main Burner Orifice and Main BurnerBF-10 Pilot Flame CharacteristicsThermostat Operation Oxygen Depletion Sensor Pilot FigureAppliance Maintenance HOW to Order Repair Parts TroubleshootingParts List Parts View Excessive Blower Wheel Noise Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes
Related manuals
Manual 20 pages 33.69 Kb