Enerco MHBF10LP, TSBF10LP, MHIR20LPT Troubleshooting CON’T, Observed Symptom Possible Cause Remedy

Page 15

TROUBLESHOOTING CON’T

OBSERVED SYMPTOM

 

POSSIBLE CAUSE

 

REMEDY

 

 

 

 

 

Buner backfiring during

1.

Burner orifice is clogged or damaged

1.

Clean burner orifice (see Cleaning and

 

Maintenance on page 13), or replace

 

 

 

combustion

 

 

 

 

 

 

burner orifice

 

2.

Burner damaged

 

 

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

Burner plaque(s) does not glow

1.

Plaque damaged

1.

Replace buner

2.

Control knob set between locked posi-

2.

Turn control knob until it locks at desired

[Infrared Only]

 

tions.

 

setting.

 

 

 

 

3. Inlet gas pressure is too low

3.

Replace gas regulator

Slight smoke or odor during

1.

Residues from manufacturing process

1.

Problem will stop after a few hours of

initial operation

 

 

operation

Heater produces a whistling

1. Turning control knob to HI position when

1.

Turn control knob to LO position and let

 

burner is cold

 

warm up for a minute.

noise when burner is lit

 

 

2. Air in gas line

2. Operate buner until air is removed from

 

 

 

line have gas line checked by local gas

 

 

 

 

 

3. Air passageways on heater blocked

 

company.

 

3. Observe minimum installation

 

 

 

 

clearances(see Figure 4 page6)

 

4.

Dirty or partially clogged burner orifice.

4.

Clean burner orifice (see Cleaning and

 

 

 

 

Maintenance on page 13), or replace

 

 

 

 

burner orifice.

White powder residue forming

1.

When heated, vapors from furniture polis,

1.

Turn heater off when using furniture

within burner box or on

 

wax, carpe cleaners, etc., turn into white

 

poils,wax, carpet cleaner or similar

adjacent walls or furniture

 

powder residue

 

products.

TROUBLESHOOTING

WARNING: If you smell gas:

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED SYMPTOM

 

POSSIBLE CAUSE

 

REMEDY

Heater produces unwanted

1.

Heater burning vapors from paint, hair

1.

Ventilate room. Stop using odor-causing

 

spray, glues, etc. See IMPORTANT

 

products while heater is running.

odors.

 

 

 

statement above

 

 

 

 

 

 

 

2.

Gas leak. See WARNING statement at

2.

Locate and correct all leaks (see Checking

 

 

top of page.

 

Gas Connections, page 8)

Heater shuts off in use (ODS

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

operates)

2.

Low line pressure

2.

Contact local gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 13)

Gas odor even when control

1.

Gas leak. See WARNING statement at

1.

Locate and correct all leaks (see Checking

 

top of page

 

Gas Connections, page 8)

knob is in OFF position

 

 

2.

Control valve is defective

2.

Replace control valve

 

 

1.

Foreign matter between control valve and

1.

Take apart gas tubing and remove foreign

Gas odor during combustion

 

burner

 

matter

2.

Gas leak. See WARNING statement at

2.

Locate and correct all leaks (see Check-

 

 

 

top of page

 

ing Gas Connections, page 8)

Heater produces a cliking/

1.

Metal expanding while heating or contract-

1.

This is common with most heaters. If noise

ticking noise just after butner is

 

ing while cooling

 

is excessive, contact qualified service

lit or shut off

 

 

 

person

Moisture/condensation noticed

1. Not enough combustion/venitlation air

1.

Refer to Fresh Air of Combustion and

on windows

 

 

 

Ventilation page 3 through 5.

15Installation instructions and Owner’s Manual

Image 15
Contents TSBF30LPT MHIR30LPT MHIR20LPT MHBF30LPT MHBF20LPTTSBF20LPT TSBF10LPPrecautions Carbon Monoxide PoisoningPropane/LP Gas Ignition System Safety DeviceThermostatic Control on Thermostat Models Local CodesDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building Ventilation from Outdoors InstallationThis Installation Requires Locating HeaterMounting Bracket Fastening Heater to WallFloor Mounting Away from Wall Connecting to GAS SupplyTest pressure in Excess of ½ psig 3.5kPa Pressure Testing Heater Gas Connections Electrical Wiring DiagramWhat to do if YOU Smell GAS Lighting Instructions Shutting OFF Burner only Pilot Stays LIT To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF HeaterBurner Flame Pattern Thermostat Control OperationInspecting Burner Pilot Flame PatternCleaning Heater Cabinet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Hole InletObserved Symptom Possible Cause Remedy TroubleshootingObserved Symptom Possible Cause Remedy Troubleshooting CON’TSpecifications IR10 LP IR20LPT IR30LPTBF10LP BF20LPT BF30LPT Technical Service Replacement PartsParts Under Warranty Parts not Under WarrantyIR30LPT Thermostat modelsBF20LPT BF30LPT IR20LPT20-235Parts List Description QTYIR20LPT BF20LPT IR30LPT BF30LPT Regulator to Thermostat Valve tube Ass’y BF10LP MHIR10LP, MHBF10LP TSIR10LP, TSBF10LPNON-Thermostat models IR10LPIR10LP BF10LP MHIR10LP, MHBF10LP, TSIR10 LP, TSBF10LPDescription QTY Warranty Information
Related manuals
Manual 24 pages 23.88 Kb

MHBF20LPT, TSIR10LP, MHIR30LPT, MHIR20LPT, TSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.