Enerco MHBF10LP Thermostatic Control on Thermostat Models, Local Codes, Safety Device, Unpacking

Page 3

Product Features

Ignitor Button

Control Knob

 

Burners

Grill

Heater

Cabinet

Front Panel

Figure 1

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensor (ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

PIEZO: BF10LP/ IR10LP – The heater is equipped with a piezo manual ignitor. This system requires no matches, batteries, or other source to light heater.

Electronic: BF20LPT/BF30LPT/IR20LPT/IR30LPT – The heater is equipped with an electronic manual ignitor. This system requires no matches, or other source to light heater, but does require one AA battery to operate ignitor.

To install or replace battery unscrew the ignitor cap (red button), insert battery and replace cap.

THERMOSTATIC CONTROL ON

THERMOSTAT MODELS

(BF20LPT, BF30LPT, IR20LPT and IR30LPT)

These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower bills.

LOCAL CODES

Install and use heater with care.

Installation must conform to local codes or in the absences of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1/NFPA 54.

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate com- bustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

ESTABLISHING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

This heater must not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The information on pages 3 through 5 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

If your home meets all of the three following criteria you must provide additional fresh air. See Ventilation Air from Outdoors, page 5.

Unusually tight construction is defined as construction where:

a.Walls and ceilings exposed to the outside atmo- sphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.Whether stripping has been added on openable windows and doors, and

c.Caulking or sealants are applied to areas such as joints around windows and door frames, between wall-ceiling joints, between wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If you home does not meet all of the three criteria above, see Determing the Type of Heater Location Space, page 4.

Confined Space and Unconfined Space

The National Fuel Gas Code, NFPA 54/ ANSI Z223.1

defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space, and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

3Installation instructions and Owner’s Manual

Image 3
Contents TSBF30LPT MHIR30LPT MHIR20LPT MHBF30LPT MHBF20LPTTSBF20LPT TSBF10LPPrecautions Carbon Monoxide PoisoningPropane/LP Gas Ignition System Safety DeviceThermostatic Control on Thermostat Models Local CodesDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building Ventilation from Outdoors InstallationThis Installation Requires Locating HeaterMounting Bracket Fastening Heater to WallFloor Mounting Away from Wall Connecting to GAS SupplyTest pressure in Excess of ½ psig 3.5kPa Pressure Testing Heater Gas Connections Electrical Wiring DiagramWhat to do if YOU Smell GAS Lighting Instructions Shutting OFF Burner only Pilot Stays LIT To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF HeaterBurner Flame Pattern Thermostat Control OperationInspecting Burner Pilot Flame PatternCleaning Heater Cabinet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Hole InletObserved Symptom Possible Cause Remedy TroubleshootingObserved Symptom Possible Cause Remedy Troubleshooting CON’TSpecifications IR10 LP IR20LPT IR30LPTBF10LP BF20LPT BF30LPT Technical Service Replacement PartsParts Under Warranty Parts not Under WarrantyIR30LPT Thermostat modelsBF20LPT BF30LPT IR20LPT20-235Parts List Description QTYIR20LPT BF20LPT IR30LPT BF30LPT Regulator to Thermostat Valve tube Ass’y BF10LP MHIR10LP, MHBF10LP TSIR10LP, TSBF10LPNON-Thermostat models IR10LPIR10LP BF10LP MHIR10LP, MHBF10LP, TSIR10 LP, TSBF10LPDescription QTY Warranty Information
Related manuals
Manual 24 pages 23.88 Kb

MHBF20LPT, TSIR10LP, MHIR30LPT, MHIR20LPT, TSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.