Enerco MHIR30LPT, TSBF10LP, MHIR20LPT Precautions, Carbon Monoxide Poisoning, Propane/LP Gas

Page 2

This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with any other gas.

*Aftermarket completion of sale, not for the purpose of resale, from the manufacturer.

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assembly, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

WARNING: Do not use any accessory not ap- proved for use with this heater.

WARNING: Any change to this heater or its controls can be dangerous.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies.

Surface of heater becomes very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Heater will remain hot for a time after shut- down. Allow heater surfaces to cool before handling.

Young children should be carefully supervised when they are in the same room with heater.

Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be replaced prior to operating the heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

PRECAUTIONS:

1.MHBF-10 LP and MHIR-10LP may be installed in a bedroom, but not a bathroom, or any place where a strong wind would shut down the appliance.

2.MHBF-20 LPT, MHBF-30 LPT, MHIR-20 LPT and MHIR-30 LPT may not be installed in a bedroom or bathroom, or any place where a strong wind would shut down the appliance.

3.This heater needs outside ventilation air to run properly. The Oxygen Depletion Sensor (ODS) safety shutoff system shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation, page 3.

4.Keep all air openings in heater clear, free of debris or any blockage. This will insure that enough air for proper combustion enters the heater.

5.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, it requires servicing.

6.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

7.Do not run heater:

Where flammable liquids or vapors are used or stored

During dusty conditions.

8.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.Do not use heater if any part has been underwater. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater.

10.Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.

11.Always run heater with control knob in a locked position. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result if control knob is left between locked positions.

DANGER: Carbon monoxide poisoning may lead to death.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas:

Propoane/LP gas is odorless. An odor making agent is added to propane/LP gas. The odor helps you detect a Propane/LP gas leak. However the odor added to propane/LP gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

2 Installation instructions and Owner’s Manual 70575 Rev. C 8/05

Image 2
Contents TSBF10LP MHBF30LPT MHBF20LPTTSBF20LPT TSBF30LPT MHIR30LPT MHIR20LPTPropane/LP Gas PrecautionsCarbon Monoxide Poisoning Local Codes Safety DeviceThermostatic Control on Thermostat Models Ignition SystemVentilation from Inside Building Determining the Type of Heater Location SpaceVentilation AIR Locating Heater InstallationThis Installation Requires Ventilation from OutdoorsFastening Heater to Wall Mounting BracketConnecting to GAS Supply Floor Mounting Away from WallTest pressure in Excess of ½ psig 3.5kPa What to do if YOU Smell GAS Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram Lighting Instructions Shutting OFF Heater To Turn OFF GAS to ApplianceOperating Your Heater Thermostat Models Shutting OFF Burner only Pilot Stays LITPilot Flame Pattern Thermostat Control OperationInspecting Burner Burner Flame PatternCleaning Burner Pilot AIR Hole Inlet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Heater CabinetTroubleshooting Observed Symptom Possible Cause RemedyTroubleshooting CON’T Observed Symptom Possible Cause RemedyBF10LP BF20LPT BF30LPT SpecificationsIR10 LP IR20LPT IR30LPT Parts not Under Warranty Replacement PartsParts Under Warranty Technical ServiceIR20LPT20-235 Thermostat modelsBF20LPT BF30LPT IR30LPTIR20LPT BF20LPT IR30LPT BF30LPT Parts ListDescription QTY Regulator to Thermostat Valve tube Ass’y IR10LP MHIR10LP, MHBF10LP TSIR10LP, TSBF10LPNON-Thermostat models BF10LPMHIR10LP, MHBF10LP, TSIR10 LP, TSBF10LP IR10LP BF10LPDescription QTY Warranty Information
Related manuals
Manual 24 pages 23.88 Kb

MHBF20LPT, TSIR10LP, MHIR30LPT, MHIR20LPT, TSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.