Enerco MHBF10LP installation instructions Blue Flame Heaters Plaque Heaters, Model # Burn Rate

Page 1

Serial Number Info on Pg 24

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

INSTALLATION INSTRUCTIONS

AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instruc- tions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.

UNVENTED LP-GAS FIRED ROOM HEATER

Blue Flame Heaters

 

Plaque Heaters

 

Model #

Burn Rate

Model #

Burn Rate

MHBF10LP/HSBF10LP/TSBF10LP

10,000 Btu/hr

MHIR10LP/HSIR10LP/TSIR10LP

10,000 Btu/hr

MHBF20LPT/HSBF20LPT/TSBF20LPT

20,000 Btu/hr

MHIR20LP/HSIR20LPT/TSIR20LPT

20,000 Btu/hr

MHBF30LPT/HSBF30LPT/TSBF30LPT

30,000 Btu/hr

MHIRLPT/HSIR30LPT/TSIR30LPT

30,000 Btu/hr

MHBF30LPT/

MHBF20LPT/

MHBF10LP/

HSBF30LPT/

HSBF20LPT/

HSBF10LP/

TSBF30LPT

TSBF20LPT

TSBF10LP

MHIR30LPT/

MHIR20LPT/

MHIR10LP/

HSIR30LPT/

HSIR20LPT/

HSIR10LP/

TSIR30LPT

TSIR20LPT

TSIR10LP

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-WHAT TO DO IF YOU SMELL GAS

Shut off gas supply

Do not try to light any appliance

Do not touch an electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and Ventila- tion section on page 3 of this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier.

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND,1 InstallationOHIO 44135instructions· 216-916and-3000Owner’s Manual70575 Rev. E 04/07

Image 1
Contents Model # Burn Rate Blue Flame Heaters Plaque HeatersWhat to do if YOU Smell GAS Carbon Monoxide Poisoning PrecautionsPropane/LP Gas Thermostatic Control on Thermostat Models Safety DeviceLocal Codes Ignition SystemVentilation AIR Determining the Type of Heater Location SpaceVentilation from Inside Building Locating Heater InstallationVentilation from Outdoors Check GAS TypeMounting Bracket Fastening Heater to WallInstalling Support Feet see figure Installing Bottom Mounting ScrewsConnecting to GAS Supply Placing Heater on Mounting BracketTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaElectrical Wiring Diagram Pressure Testing Heater Gas ConnectionsOperating Your Heater What to do if YOU Smell GASFor IR Heaters only Lighting InstructionsShutting OFF Heater To Turn OFF GAS to ApplianceShutting OFF Burner only Pilot Stays LIT Turn control knob clockwise to the PILOT/IGN positionInspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame PatternCleaning ODS/PILOT and Burner Cleaning and MaintenanceCleaning Burner Pilot AIR Hole Inlet Cleaning Heater CabinetObserved Symptom Possible Cause Remedy TroubleshootingControl knob not in pilot position Observed Symptom Possible Cause Remedy Troubleshooting CON’TIR10 LP IR20LPT IR30LPT SpecificationsBF10LP BF20LPT BF30LPT Parts Under Warranty Replacement PartsParts not Under Warranty Technical ServiceBF20LPT BF30LPT Thermostat modelsIR20LPT IR30LPT Thermostat models Parts ListIR20LPT, IR30LPT, BF20LPT, BF30LPT IR20LPT BF20LPT IR30LPT BF30LPT70683 Not sold separately Must purchase Assembly Items not shown70684 31-1 70685BF10LP NON-Thermostat models IR10LPIR10LP, BF10LP, IR10 LP, BF10LP Non-Thermostat modelDescription QTY IR10LP BF10LPDescription QTY Keep this warranty Warranty InformationModel Serial No Date Purchased Ansi Z21.11.2b-2004
Related manuals
Manual 24 pages 60.62 Kb Manual 24 pages 35.26 Kb

MHBF20LPT, TSBF20LPT, MHBF10LP, TSBF10LP, HSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.