Enerco TSBF20LPT Locating Heater, Ventilation from Outdoors, Installation, Check GAS Type

Page 5

 

 

 

 

 

 

 

 

 

 

 

 

VENTILATION AIR

 

 

Ground joint union

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test gauge connection*

OUTLET AIR

VENTILATED

 

 

 

 

Sediment trap

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tee joint

OUTLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO ATTIC

 

 

Pipe wrench

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO CRAWL

 

*A CSA/AGA certified equipment shutoff valve with 1/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NPT tap is an acceptable alternative to test gauge

INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection. Purchase a CSA/AGA certified equipment

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shutoff valve from your dealer. See Accessories, page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTILATION CRAWL SPACE

 

17.

 

 

 

 

 

 

 

 

 

Figure 3.

 

 

 

 

 

LOCATING HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

This heater is designed to be mounted on the wall. The

Ventilation from Outdoors

 

 

 

 

 

 

 

 

 

 

heater can also be located on a non-combustible floor,

If necessary, provide extra fresh air by using ventilation

 

away from a wall by using the floor mounting stands

grilles or ducts. Connect these items directly to the

 

included with the heater. If installed on combustible

outdoors or spaces open to the outdoors. These

 

flooring such as carpeting, tile or other combustible

include attics* and crawl spaces. Follow the National

 

material other than wood flooring, the heater must be

Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air

 

placed on a wood panel the full width and depth of the

for Combustion and Ventilation for required size of

 

appliance.

ventilation grilles or ducts.

 

 

 

 

 

For convenience and efficiency, install the heater:

*IMPORTANT: Do not provide openings for inlet or

 

 

Where there is easy access for operation,

outlet into attic. If attic has a thermostat-controlled

 

 

 

inspection, and service.

power vent, heated air entering the attic will activate

 

 

 

 

 

In the coldest part of the room.

the power vent.

 

 

 

 

 

 

 

 

 

 

 

 

If planning to use fan, locate heater near an

IMPORTANT: Vent-free heaters add moisture to the

 

 

air. Although this is beneficial, installing heater in

 

 

 

electrical outlet.

rooms without enough ventilation air may cause

 

 

CAUTION: If you install the heater in a home garage:

mildew to form from too much moisture. See Fresh

 

 

Heater pilot and burner must be at least 18

Air for Combustion and Ventilation, pages 3 through

 

 

 

 

 

inches above floor.

5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locate heater where moving vehicle will not hit it.

INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTICE: This heater is intended for use as supplemental

 

 

CAUTION:This heater creates warm air currents.

 

 

These currents move heat to wall surfaces next to heater.

heat. Use this heater along with your primary heating

 

 

 

 

Installing heater next to vinyl or cloth wall covering or

system. Do not install this heater as your primary heat

 

 

 

 

operating heater where impurities (such as tobacco smoke,

source. If you have a central heating system, you may

 

 

 

 

aromatic candles, cleaning fluids, oil or kerosene lamps,

run system’s circulating blower while using heater. This

 

 

 

 

etc.) are present in the air may discolor walls.

will help circulate the heat throughout the house. In the

 

 

 

 

 

 

event of a power outage, you can use this heater as your

 

 

WARNING: Never install the heater:

 

 

In a bathroom.

primary heat source for the duration of the outage.

 

 

WARNING: A qualified service person must install

 

 

• In a bedroom (IR20LPT, IR30LPT, BF20LPT or

heater. Follow all local codes.

 

 

 

 

 

 

 

BF30LPT)

CHECK GAS TYPE

 

 

 

 

 

 

• In a recreational vehicle.

 

 

 

 

 

 

Where curtains, furniture, clothing, or other

Use only LP-gas.If your gas supply is not LP-gas, do

 

 

not install heater. Call dealer where you bought heater

 

 

 

flammable objects are less than 36 inches from

for proper type heater.

 

 

 

 

 

 

 

the front, top, or sides of the heater.

THIS INSTALLATION REQUIRES:

 

 

 

 

 

 

• As a fireplace insert

 

 

 

 

 

 

• In high-traffic areas

Before installing heater, make sure you have the items

 

 

listed below:

 

 

 

 

 

 

 

 

 

 

2345

 

 

 

 

 

• In windy or drafty areas

Piping (check local codes)

 

 

 

 

 

WARNING: Heater must be mounted to maintain the

Sealant (resistant to LP_Gas)

 

 

 

 

 

minimum clearances shown in Figure 4. If possible,

 

 

 

 

 

provide greater clearances from the floor, ceiling, and

Equipment shutoff valve*

 

 

 

 

 

 

 

 

 

 

joining walls.

 

 

 

234234

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

Installation instructions and Owner’s Manual

 

 

 

 

 

 

 

 

 

 

 

Image 5
Contents What to do if YOU Smell GAS Blue Flame Heaters Plaque HeatersModel # Burn Rate Propane/LP Gas PrecautionsCarbon Monoxide Poisoning Thermostatic Control on Thermostat Models Safety DeviceLocal Codes Ignition SystemVentilation from Inside Building Determining the Type of Heater Location SpaceVentilation AIR Locating Heater InstallationVentilation from Outdoors Check GAS TypeMounting Bracket Fastening Heater to WallInstalling Support Feet see figure Installing Bottom Mounting ScrewsConnecting to GAS Supply Placing Heater on Mounting BracketTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaElectrical Wiring Diagram Pressure Testing Heater Gas ConnectionsOperating Your Heater What to do if YOU Smell GASFor IR Heaters only Lighting InstructionsShutting OFF Heater To Turn OFF GAS to ApplianceShutting OFF Burner only Pilot Stays LIT Turn control knob clockwise to the PILOT/IGN positionInspecting Burner Thermostat Control OperationPilot Flame Pattern Burner Flame PatternCleaning ODS/PILOT and Burner Cleaning and MaintenanceCleaning Burner Pilot AIR Hole Inlet Cleaning Heater CabinetControl knob not in pilot position TroubleshootingObserved Symptom Possible Cause Remedy Observed Symptom Possible Cause Remedy Troubleshooting CON’TBF10LP BF20LPT BF30LPT SpecificationsIR10 LP IR20LPT IR30LPT Parts Under Warranty Replacement PartsParts not Under Warranty Technical ServiceIR20LPT IR30LPT Thermostat modelsBF20LPT BF30LPT Thermostat models Parts ListIR20LPT, IR30LPT, BF20LPT, BF30LPT IR20LPT BF20LPT IR30LPT BF30LPT70683 Not sold separately Must purchase Assembly Items not shown70684 31-1 70685BF10LP NON-Thermostat models IR10LPIR10LP, BF10LP, IR10 LP, BF10LP Non-Thermostat modelDescription QTY IR10LP BF10LPDescription QTY Keep this warranty Warranty InformationModel Serial No Date Purchased Ansi Z21.11.2b-2004
Related manuals
Manual 24 pages 60.62 Kb Manual 24 pages 35.26 Kb

MHBF20LPT, TSBF20LPT, MHBF10LP, TSBF10LP, HSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.